1771-HODS – Converter Option ODS Module (PLC-5 Series)
Product Overview
The 1771-HODS from Allen-Bradley / Rockwell Automation belongs to the PLC-5 series. It is a Converter Option ODS module for the 123 Motion Control System. This module links the ODS terminal and handheld pendant to the motion controller. It supports RS-232 and RS-422 communication. The pendant connects up to 8 m (25 ft) from the RS-232 port. The ODS terminal connects up to 393 m (1200 ft) from the RS-422 connector. With the 1771-HLL longline option, both devices reach up to 393 m. Four DIN-rail termination panels offer flexibility for Temposonic, encoder, and resolver transducers.
Key Technical Specifications
- Manufacturer: Allen-Bradley / Rockwell Automation
- Series: PLC-5
- Part Number: 1771-HODS
- Module Type: Converter Option ODS
- Compatibility: 123 Motion Control System
- Communication Ports: RS-232, RS-422
- Longline Option: 1771-HLL (extends range to 393 m)
- Mounting: DIN Rail
- Termination Panels: 4 available (Temposonic, Encoder, Resolver)
- Pendant Distance (RS-232): Up to 8 m (25 ft) standard, 393 m with longline
- ODS Terminal Distance (RS-422): Up to 393 m (1200 ft) standard, extended with longline
Communication & Distance Capabilities
- RS-232 port: Connects handheld pendant (up to 8 m standard)
- RS-422 port: Connects ODS terminal (up to 393 m standard)
- Longline option (1771-HLL): Extends both pendant and ODS to 393 m (1200 ft)
- Data format: Compatible with ODS configuration protocol
- Signal integrity: Maintains reliable communication over extended distances
Termination Panels & Transducer Support
- Temposonic panel: Supports linear displacement transducers
- Encoder panel: Supports 1 axis with external power for encoders
- Resolver panel: Supports 1 axis in single or dual resolver configurations
- Mounting: All panels are DIN-rail mounted for easy installation
- Flexibility: Panels adapt to various motion feedback devices
Installation & Mounting Guide
- Mounting type: DIN Rail (standard 35 mm)
- Panel placement: Use provided termination panels for specific transducers
- Cable routing: Keep RS-232 and RS-422 cables separated from power lines
- Longline installation: Insert 1771-HLL option between module and device
- Grounding: Connect module ground to the DIN rail for noise immunity
Debugging, Maintenance & Diagnostics
- LED indicators: Status LEDs for power and communication activity
- Diagnostic tools: Use ODS terminal software to monitor module status
- Fault detection: Automatic error reporting via RS-232/RS-422
- Maintenance: Clean connectors and check cable integrity periodically
- Firmware: Field-upgradeable via ODS configuration utility
Compatibility & System Integration
- Primary system: 123 Motion Control System
- PLC family: PLC-5 series (1771 chassis)
- Supported devices: ODS terminal, handheld pendant, Temposonic, encoder, resolver
- Communication protocols: RS-232 and RS-422 (point-to-point)
- Option card: 1771-HLL longline adapter for extended reach
Environmental & Immunity (General)
- Operating temperature: 0…60 °C (typical industrial range)
- Storage temperature: -40…85 °C
- Humidity: 5…95 % non-condensing
- Vibration: 5 g at 10…500 Hz (tested)
- EMC immunity: Complies with industrial standards (EN 61000-6-2)
Certifications & Compliance
- UL: Listed for industrial control equipment
- CSA: Certified for use in Canada
- CE: Marked for European market
- RoHS: Compliant (restriction of hazardous substances)
Package Contents & Warranty
- 1 × 1771-HODS Converter Option ODS Module
- 1 × Installation manual (printed)
- 1 × Configuration software CD (optional)
- Warranty: 12 months against manufacturing defects
- Shipping: FedEx, UPS, or DHL (express, with tracking)
Typical Applications
- Motion control systems using ODS configuration (123 series)
- Handheld pendant operation for machine setup and jogging
- Linear displacement measurement with Temposonic transducers
- Single or dual resolver feedback for positioning axes
- Encoder-based velocity and position control (1 axis)
Diagnostic Capabilities
- Real-time communication status (TX/RX activity)
- Fault codes transmitted to ODS terminal or pendant display
- Self-test on power-up verifies internal circuitry
- Loopback test via RS-232/RS-422 for cable integrity check
Frequently Asked Questions (FAQ)
- Q: Does the 1771-HODS work with other PLC-5 modules?
A: Yes, it installs in a 1771 chassis alongside other I/O modules. - Q: Can I use the longline option for both RS-232 and RS-422?
A: Yes, the 1771-HLL extends both communication channels up to 393 m. - Q: What is the maximum cable length without the longline?
A: RS-232: 8 m; RS-422: 393 m. - Q: Which termination panel do I need for a Temposonic transducer?
A: Use the dedicated Temposonic panel (one of the four available). - Q: Does the module support dual resolver inputs?
A: Yes, the resolver panel supports single or dual resolver configurations. - Q: Is the 1771-HODS still supported by Rockwell?
A: It is considered legacy but fully supported via third-party and surplus channels like Oiltech Controls.
Why Buy From Oiltech Controls?
- 15+ years in industrial automation spare parts
- Global shipment with FedEx, UPS, DHL
- Tested industrial surplus / refurbished options
- 12-month warranty on all products
- Technical verification before dispatch
- Support for obsolete control systems
Contact: info@oiltechcontrols.com | +86 158 8020 0923 (WhatsApp)
Copyright © 2026 Oiltech Controls Limited. All rights reserved.
Original Source: https://www.oiltechcontrols.com/










Reviews
There are no reviews yet.