Honeywell FS24X-911-21-1 Flame Detector
FS24X-911-21-1 is a high-performance flame detector.
It serves harsh industrial fire zones.
The design handles heat and vibration.
The wide field monitors large areas.
Response time stays fast and stable.
Product Identity
- Brand: Honeywell
- Part Number: FS24X-911-21-1
- Model Type: Industrial flame detector
- Condition: New and factory sealed
- Certifications: FM, cFM, ATEX, IECEx
Enclosure and Build
- Housing: Copper-free aluminum
- Optional 316 stainless steel shell
- Diameter: 4.81 in or 122.24 mm
- Height: 4.35 in or 110.49 mm
- Mount Center: 5.50 in spacing
- Entry: Dual ¾ in NPT or 25 mm conduit
- Weight: 1.7 kg aluminum version
- Protection: IP66 and NEMA 4X
- Vibration: Meets MIL-STD-810C
Electrical Interface
- Input Voltage: 18 to 32 VDC
- Normal Draw: 60 mA typical
- Alarm Draw: 85 mA max
- Heater Mode: up to 235 mA
- Relay Output: 1 A at 24 VDC
- Analog Output: 0–20 mA selectable source or sink
- Fault Signal: <0.6 mA
- Normal Signal: 4 mA
- Alarm Signal: 20 mA
- Terminal Range: 12–22 AWG stranded wire
Environmental Limits
- Operating Range: -60°C to +85°C
- Storage Range: -55°C to +105°C
- Humidity: up to 95 percent RH
- Short-term condensation allowed
- Stable optics under dusty air flow
Detection Performance
- Field of View: 90° horizontal and 80° vertical
- Spectral Band: 0.4 to 5.0 microns
- Response Speed: 2 to 5 seconds
- Reference Fire: 1 sq ft heptane at 200 ft
- False Alarm Rejection: Advanced multi spectrum logic
- View Stability: High immunity to sunlight
Key Advantages
- Early fire recognition.
- Wide viewing coverage.
- Low current demand.
- Hazard-zone approvals.
- Robust aluminum housing.
- Dual output options.
- Quick system integration.
Typical Installation Sites
- Oil tank farms.
- Gas compressor rooms.
- Turbine enclosures.
- Loading platforms.
- Chemical process areas.
Warranty and Shipping
- Warranty: 12 months factory support.
- Brand new with sealed packing.
- Inspection before dispatch.
- Courier Options: FedEx, UPS, DHL.
- Worldwide express delivery.
FAQ
- Can the detector face outdoor sunlight?
- Yes, optical filters reduce false triggers.
- Is heater operation mandatory?
- No, the heater is only used to prevent lens fogging.
- Does cable length affect output accuracy?
- Signal remains stable within rated load limits.
- Can relays drive alarm horns directly?
- They can control low-current devices or relays.
- How often should the lens be cleaned?
- Check during routine safety inspections.
Contact Information Inquiries:
info@oiltechcontrols.com |
+86 158 8020 0923
Copyright © 2025 Oiltech Controls Limited. All rights reserved.
Original Source: https://www.oiltechcontrols.com/
Partner PLCDCS HUB Limited. All rights reserved.





Reviews
There are no reviews yet.