Product Introduction: Safe Analog Output
The Schneider Electric 140AIO33000 is a special output module. It is designed for safe use in hazardous areas. This module provides precise analog control signals. It connects to valves and actuators in dangerous locations.
Main Features & Selling Points
- Hazardous Area Certified: ATEX/IECEx approved for intrinsic safety.
- High Channel Density: 8 analog outputs in one module.
- Superior Accuracy: ±0.2% of full scale for reliable control.
- Fast Response: 4 ms update time and 1 ms setting time.
- Robust Protection: Internal fuse and 1780 Vrms isolation for safety.
Detailed Technical Data
- Brand & Model: Schneider Electric 140AIO33000
- Module Type: Intrinsically Safe Analog Output.
- Output Channels: 8 isolated channels.
- Output Signals: 0-20mA, 4-20mA, 0-25mA.
- Base Accuracy: ±0.2% of full scale at 25°C.
- Temperature Drift: Low, at 40 ppm/°C.
- Linearity Error: ±1 LSB.
- Max Load Resistance: 500 Ohms.
- Power Consumption: 12.5 Watts.
- Bus Current Needed: 2.5 Amps.
- Isolation: 1780 Vrms between channels and bus.
- Update Rate: 4 milliseconds.
- Response Time: 1 ms to ±0.1% of final value.
- Safety Markings: CE, II1 G/D-EEx ia IIC, ATEX, FM.
- Operating Temperature: 0°C to 60°C.
- Module Weight: 0.3 kg (0.7 lbs).
Warranty & Delivery Options
- Full 12-month product warranty included.
- Express global shipping via FedEx, UPS, and DHL.
Frequently Asked Questions
What does “intrinsically safe” mean for this module?
It means the module limits electrical energy. It cannot spark and ignite flammable gases or dust. This allows safe use in classified hazardous areas.
What type of devices can I control with it?
You can control IS-certified devices like valve positioners, I/P converters, and variable speed drives in hazardous zones.
What is a key wiring consideration?
You must use properly certified intrinsic safety barriers or isolators between this module and field devices. The module itself is not a barrier.
Can I replace the module while power is on (hot swap)?
No. Hot swapping is not allowed for intrinsically safe modules. You must power down the system to maintain safety certification.
How do I select the right analog output module?
Choose the 140AIO33000 if you need to send control signals (like 4-20mA) into a Class I, Division 1 hazardous area from a Quantum PLC.
Contact for Purchase & Support
- Email: info@oiltechcontrols.com
- Phone/WhatsApp: +86 158 8020 0923
Copyright © 2025 Oiltech Controls Limited. https://www.oiltechcontrols.com/ All rights reserved.
Partner PLCDCS HUB Limited https://plcdcshub.com/
Powergear X Automation Limited https://www.powergearx.com/
All rights reserved.










Reviews
There are no reviews yet.