The Honeywell TC-POB041 is a 4-channel digital output module designed for intrinsically safe applications in process and factory automation. It delivers reliable switching at up to 10 kHz, with fast 1 ms response on all channels and diagnostic feedback per channel. This module suits engineers who need compact, certified I/O for hazardous areas without compromising on speed or fault visibility.
Technical Specifications – Engineered for Precision and Safety
| Brand / Model | Honeywell / TC-POB041 |
| Output Channels | 4, referenced to single supply |
| Output Capacity | 11 V at 45 mA per channel |
| Switching Frequency | 10 kHz (max) |
| Response Time | 1 ms all channels |
| Intrinsic Safety | Europe: II (1) 2G EEx ia/ib IIB/IIC T4 (CENELEC) |
| Permissible Field Circuit | Uo = 27.4 V, Io = 110 mA |
| Max Inductance (Lo) | 8 mH (EEx ia IIB) / 2 mH (EEx ia IIC) |
| Max Capacitance (Co) | 677 nF (EEx ia IIB) / 87 nF (EEx ia IIC) |
| Input Voltage | Intrinsically safe power via Terminal Base |
| Power Dissipation | 5 W |
| Galvanic Isolation | Output / Backplane Bus; Output / Power Supply (per DIN EN 50020). No isolation between outputs. |
| Temperature Range | Operating: –20°C to 70°C (253K to 343K) / Storage: –20°C to 100°C |
| Humidity | 95% max, non-condensing |
| Shock / Vibration | 15 g peak 11 ms / 2 g @ 10–500 Hz (IEC 68-2-6) |
| Protection Class | IP20 (IP54 or better required for field installation) |
| Dimensions (H×W×D) | 76 × 94 × 46 mm (3.0 × 3.7 × 1.8 in) |
| Weight | 0.282 kg (0.62 lb) |
| Keyswitch Position | 7 |
| Certifications | CENELEC (Europe): II (1) 2G EEx ia/ib IIB/IIC T4; DMT 99 ATEX E 026 X; CE; EMC per DIN EN 50081-2 / 50082-2 / NAMUR NE 21 |
Diagnostic Capabilities – Fast Fault Detection, Clear Indication
- Lead breakage and short circuit detection per channel.
- Alarm signal via backplane bus and channel LED flashing red on fault.
- Configurable fault detection delay – applies to all channels.
- Latch mode configurable – module-wide, for fault persistence.
- De-energized failure state ensures safe shutdown.
Installation Guide – Designed for Efficiency
- Mount on Terminal Base (intrinsically safe power supplied through base).
- Use shielded multicore cable to meet EMC protection class.
- Observe Keyswitch Position 7 for correct slot assignment.
- Field installation requires separate housing IP54 or better (module is IP20).
- Wire outputs referenced to a single supply; no isolation between output channels.
Commissioning and Maintenance – Built for Uptime
- Module-level fault detection delay and latch mode can be configured once for all channels.
- LED flashing red speeds up troubleshooting without external tools.
- Hot-swap friendly when used with compatible Terminal Base (verify system procedure).
- Diagnostics via backplane bus allow remote alarm monitoring.
- No internal fuses or user-serviceable parts – reduce maintenance touchpoints.
Compatibility Notes – Integration Without Surprises
- Designed for Honeywell Intrinsically Safe I/O systems using Terminal Base.
- Supports vendor-specific bus for intrinsically safe input.
- Complies with DIN EN 50014: 1992, DIN EN 50020: 1994, DIN EN 50284: 1997.
- EMC per DIN EN 50081-2, DIN EN 50082-2, NAMUR NE 21 – use shielded cable.
- No galvanic isolation between outputs – plan common supply architecture.
Certifications and Standards – Trusted for Hazardous Areas
- CENELEC (Europe): II (1) 2G EEx ia/ib IIB/IIC T4
- ATEX: DMT 99 ATEX E 026 X
- CE Conformity (EMC protection class requires shielded multicore cable)
- Climatic conditions per DIN IEC 721
- Pollution gas test: G3 per ISA-S71.04-1985
Typical Application Scenarios – Where the TC-POB041 Excels
- Hazardous area valve and actuator control requiring intrinsically safe outputs.
- High-speed solenoid or relay driving up to 10 kHz.
- Process skids with 4 discrete outputs and fast fault feedback.
- Legacy Honeywell I/O upgrades where Keyswitch Position 7 and Terminal Base compatibility matter.
- Remote sites needing diagnostics via backplane and clear LED indication.
Why Buy From Oiltech Controls?
- 15+ years of hands-on industrial automation spare parts experience.
- Global shipment support – we ship worldwide with FedEx, UPS, and DHL.
- Tested industrial surplus and refurbished options – every unit verified before dispatch.
- 12-month warranty on every module we supply.
- Technical verification before shipment – we check compatibility and condition.
- Support for obsolete control systems – keep your line running when OEM support ends.
Questions or quotes? Email us at info@oiltechcontrols.com or message +86 158 8020 0923 on WhatsApp. We respond fast with technical data and lead times.
FAQ – Quick Answers for Engineers
- Q: What is the switching frequency of the TC-POB041?
A: Up to 10 kHz on all channels. - Q: What is the response time?
A: 1 ms module input/output delay on all channels. - Q: Is channel-to-channel isolation provided?
A: No. Outputs are referenced to a single supply; there is no galvanic isolation between outputs. - Q: What is the failure state?
A: De-energized state for safe shutdown. - Q: How are faults indicated?
A: Alarm signal via backplane bus and channel LED flashing red. - Q: What protection class does the module have?
A: IP20; for field installation use a separate housing IP54 or better.
Packaging and Shipping
- 1 × Honeywell TC-POB041 Digital Output Module (4-points)
- Anti-static packaging and protective carton
- Shipping via FedEx, UPS, or DHL (tracked, insured options available)
- Documentation: technical datasheet and conformity references included on request
12-month warranty covers functional defects under normal use. Contact info@oiltechcontrols.com for warranty claims or technical support. We also provide pre-shipment verification to confirm your module matches the required specification.
Copyright © 2026 Oiltech Controls Limited. All rights reserved.
Original Source: https://www.oiltechcontrols.com/
All rights reserved.








Reviews
There are no reviews yet.