XNX-UTSE-NNNNN – Honeywell Universal Gas Transmitter
XNX-UTSE-NNNNN belongs to the Honeywell XNX Series. This stainless steel transmitter offers universal gas detection. It works with electrochemical, catalytic bead, and infrared sensors. The device supports HART, Modbus, and Fieldbus protocols. It suits oxygen and toxic gas monitoring in industrial environments.
Key features: UL/CSA and ATEX approved. IP66/NEMA 4X enclosure. Hot-swappable and intrinsically safe sensor connection. Backlit LCD with magnetic wand interface. Three SPCO relays (2 alarm, 1 fault).
Technical Specifications
- Brand: Honeywell Analytics
- Model: XNX-UTSE-NNNNN
- Product Type: Universal gas detector transmitter
- Housing: Painted SS316 stainless steel
- Conduit Entries: Five 3/4″ NPT
- Operating Voltage: 16–32 V DC (24 V nominal)
- Power Consumption: 6.2–13.2 W (depends on sensor)
- Signal Output: 4-20 mA with HART (source, sink, or isolated)
- Optional Comms: Modbus RTU, FOUNDATION Fieldbus
- Relays: 3 × SPCO @ 250 V AC / 5 A
- Display: Backlit LCD, magnetic wand interface
- Protection: IP66 / NEMA 4X
- Operating Temp: –40 °C to +65 °C
- Humidity: 0–99 % RH (non-condensing)
- Pressure Range: 80–120 kPa
- Mounting: Wall or pipe mount (integral lugs)
- Weight: ≈ 5 kg (SS version)
- Certifications: UL, CSA, ATEX, SIL2
- Sensor Connection: Intrinsically safe, hot-swappable
- Data Retention: 3-year RTC backup
Measurement & Performance
- Measuring Range: O2 0-25% VOL (and other toxic gases)
- Response Time: T90 < 30 seconds (typical)
- Linearity: ±2% of full scale
- Resolution: 0.1% VOL (O2)
- Sensitivity: High accuracy with low drift
- Temperature Range: –40 °C to +65 °C
- Environmental Resistance: IP66, NEMA 4X, 0-99% RH
- Immunity: Excellent RFI/EMI rejection
Installation Guide
- Mount on wall or pipe using integral lugs.
- Use 3/4″ NPT conduit entries for wiring.
- Connect power: 16–32 V DC (24 V nom).
- Wire 4-20 mA loop (source, sink, or isolated).
- Use HART, Modbus, or Fieldbus as needed.
- Hot-swap sensors without powering down.
- Refer to user manual for SIL2 setup.
Debug & Maintenance
- Magnetic wand interface for non-intrusive configuration.
- Backlit LCD shows real-time readings and faults.
- Diagnostic LEDs indicate alarm and fault status.
- Auto-calibration routine via HART or local menu.
- 3-year data retention keeps logs and settings.
- Easy access to sensor terminals for replacement.
Compatibility
- Compatible with all Honeywell electrochemical, catalytic bead, and IR sensors.
- Supports HART 7, Modbus RTU, and FOUNDATION Fieldbus H1.
- Works with Modicon Quantum and other DCS/PLC systems.
- Intrinsically safe sensor connection (hot-swappable).
- 3-wire 4-20 mA loop for standard analog integration.
Certifications & Approvals
- UL: Class I, Div 1 Groups A, B, C, D
- CSA: Certified for hazardous locations
- ATEX: Zone 1, Category 2G
- SIL2: Suitable for safety instrumented systems
- NEMA 4X / IP66: Watertight and corrosion-resistant
Package Contents
- 1 × XNX-UTSE-NNNNN Transmitter
- 1 × Magnetic wand for configuration
- 1 × Installation and quick start guide
- Cable glands and mounting hardware
- Sensor (ordered separately or included per configuration)
Warranty & Shipping
- Warranty: 12 months against defects.
- Shipping: FedEx, UPS, DHL – global express.
- Items are tested and verified before shipment.
- Surplus/refurbished options available with full warranty.
Typical Applications
- Oil & gas refineries – toxic and oxygen monitoring.
- Chemical plants – leak detection and area monitoring.
- Pharmaceutical manufacturing – oxygen control.
- Water/wastewater treatment – H2S and O2 monitoring.
- Mining and steel mills – combustible gas detection.
Diagnostic Capabilities
- Continuous self-test and sensor health check.
- Fault relay triggers on sensor failure or low signal.
- Real-time clock for data logging with timestamp.
- HART diagnostic variables for predictive maintenance.
- Modbus/Fieldbus status registers for remote diagnostics.
Frequently Asked Questions
- What sensors are compatible? All Honeywell electrochemical, catalytic bead, and IR sensors.
- Can I use it with Modbus? Yes, optional Modbus RTU and FOUNDATION Fieldbus.
- Is it SIL rated? Yes, SIL2 certified for safety applications.
- How to configure without a PC? Use the magnetic wand and local LCD interface.
- What is the power requirement? 16–32 V DC (24 V nom).
- Does it support hot swapping? Yes, sensors are hot-swappable.
Why Buy From Oiltech Controls?
- Over 15 years of industrial automation expertise.
- Global shipment support – fast and reliable.
- Tested surplus and refurbished options with warranty.
- 12-month warranty and technical support.
- Every unit verified before dispatch.
- We support obsolete control systems including Modicon Quantum.
Contact us: info@oiltechcontrols.com | +86 158 8020 0923
Copyright © 2026 Oiltech Controls Limited. All rights reserved.