Quick Product Insight
- Manufacturer: Yokogawa
- Model: AAI141-S50/K4A00
- Module Type: Analog Input
- Signal: 4 to 20 mA DC
- Channels: 16, non-isolated
- Built for dense signal acquisition.
- Compatible with Yokogawa Centum VP.
Main Benefits
- High channel count in a small footprint.
- HART access for smart transmitters.
- Low power use reduces cabinet heat.
- Stable readings under load change.
- Simple wiring and fast setup.
Signal Handling Performance
- Accepts standard 4–20 mA loops.
- Handles input current up to 27 mA.
- Accuracy within ±16 microamp.
- Update cycle of 10 milliseconds.
- Step response time of 100 milliseconds.
Input Circuit Behavior
- Input resistance adjusts with loop load.
- High resistance when power is off.
- Protects transmitters during restart.
- Stable for long cable distances.
Loop Power and Channel Setup
- Built-in loop supply for field devices.
- Supports two-wire transmitters.
- Supports four-wire transmitters.
- Each channel set by pin selection.
- Current limit improves loop safety.
HART Communication Features
- HART communication enabled.
- Allows remote device checking.
- Supports parameter reading.
- No effect on analog signal speed.
Suffix and Option Tree
- Model Family
- AAI141 Analog input module
- Suffix Codes
- S Standard communication with HART
- 5 No explosion protection
- 0 Basic configuration
- Option Code
- K4A00 KS cable interface adapter
- For AEA4D terminal board
Power and Mechanical Data
- Current draw at 5 V DC: 310 mA.
- Current draw at 24 V DC: 450 mA.
- Lightweight module at 0.2 kg.
- Easy handling during installation.
Wiring and Integration
- Pressure clamp terminal support.
- KS cable connection available.
- MIL connector cable supported.
- Clean layout reduces wiring errors.
Typical Application Areas
- Flow and level measurement.
- Pressure transmitter inputs.
- General process monitoring.
- System expansion projects.
Warranty and Delivery
- 12-month warranty included.
- Secure industrial packaging.
- Worldwide shipping via FedEx.
- UPS and DHL options available.
Professional FAQ
- When should I choose a non-isolated module?
- When loops share a common reference.
- Is this module good for cabinet upgrades?
- Yes. It fits high-density layouts.
- Does HART work on all channels?
- Yes. Each channel supports HART.
- How do I pick between AAI141 and AAI143?
- Choose AAI141 for non-isolated needs.
- Is this module future-ready?
- Yes. It supports smart devices.
Contact Information
- Email: info@oiltechcontrols.com
- WhatsApp: +86 158 8020 0923
Copyright © 2026 Oiltech Controls Limited. All rights reserved.
Original Source:
https://www.oiltechcontrols.com/
Partner
PLCDCS HUB Limited. All rights reserved.










Olivia Carter –
This Yokogawa AAI141-S50/K4A00 arrived brand new and was shipped extremely quickly. Installation was straightforward, and it integrated seamlessly into our plant control system. The module is reliable and has been performing flawlessly in real-time data acquisition. Their customer support guided us through configuration, making the whole experience professional and smooth. Highly recommended!