1606-XLE240EN Allen-Bradley Essential Power Supply, 24 V DC, 240 W
The 1606-XLE240EN belongs to the Allen-Bradley Bulletin 1606-XL Essential family. It delivers 24 V DC at 10 A from a 120 V-class single-phase feed. Output trims from 24 to 28 V DC. A DC OK relay contact gives a dry status signal to the PLC. An NTC limiter tames inrush current. Dynamic 120% power boost works below +45 °C. Screw terminals hold field wiring tight. The unit mounts on DIN rail or a flat wall. Rockwell still lists it as active as of October 2026.
Quick Take
Allen-Bradley 1606-XLE240EN, 240 W, 24 V DC, 10 A, 120 V AC single phase. DC OK relay, 120% boost, screw terminals. 12-month warranty, 24 to 28 hour dispatch, FedEx UPS DHL.
Why Buy From Oiltech Controls?
- More than 15 years of hands-on industrial automation spare parts work
- Global shipment support with FedEx, UPS, and DHL
- Tested industrial surplus and refurbished options where available
- 12-month warranty on every part we ship
- Technical verification before each shipment leaves the warehouse
- Support for obsolete control systems still running on site
Core Electrical Data
- Model: 1606-XLE240EN
- Brand: Allen-Bradley
- Series: Bulletin 1606-XL Essential
- Input: 100 V AC nominal, operational 90 to 132 V AC, 50/60 Hz
- Output: 24 V DC nominal, adjustable 24 to 28 V DC
- Output current: 10 A at 24 V, 240 W max
- Efficiency: 91.3% typical
- Hold-up time: over 46 ms typical at 120 V
- Power factor: 0.57 typical
- Ripple and noise: 50 mV maximum
Hardware, Mounting, Protection
- Mounting: DIN rail and wall mounting
- Connection: screw terminals
- DC OK relay contact: present, dry signal contact only
- Inrush limiter: NTC type
- Dynamic 120% power boost available under +45 °C
- Dimensions (H×W×D): 124 × 60 × 117 mm body
- Weight: 0.70 kg
- Protection rating: IP20
- Approvals: UL 60950-1, cUL, CE marked
- Built-in ports: none. No protocol stack, no fieldbus
Environmental Envelope
- Operating temperature: 0 °C lower bound. Upper bound not published numerically on the product page
- Storage temperature: -25 °C lower bound. Upper bound not published numerically on the product page
- Relative humidity: 5 to 95%, non-condensing
- Keep clear of corrosive gas, flammable gas, and heavy dust
- Mount vertically where airflow is weak
Where It Fits
- North American panels fed from 120 V AC single phase
- 24 V DC buses driving relays, sensors, and small drives
- Systems that need a hardwired DC OK status back to the PLC
- Loads with short inrush peaks that need 120% boost headroom
- Spare stock for active Bulletin 1606-XL Essential installs
Oiltech Controls Review
- The DC OK relay is the standout feature here. It saves a separate monitor relay.
- 91.3% efficiency keeps heat low inside a 60 mm wide body.
- 120% boost handles contactor pull-in without tripping the supply.
- Screw terminals suit field techs who prefer a torque wrench over push-in clamps.
- Active lifecycle status makes it a low-risk spare to hold.
Oiltech Controls Insight
- Set output to 24.5 V. It absorbs line drop on long DC runs.
- Boost drops above +45 °C. Check panel ambient before relying on it.
- Wire the DC OK contact to a PLC input. It flags supply faults early.
- Torque screw terminals to the value on the housing. Loose screws cause hot spots.
- Record the adjusted voltage and boost margin on the panel card.
Warranty and Dispatch
- 12-month warranty on all supplied units
- Dispatch within 24 to 28 hours after order confirmation
- Shipping by FedEx, UPS, and DHL
- Tracking number sent by email after dispatch
- Technical verification before shipment
FAQ
Q: What does the DC OK relay actually do?
A: It closes when output voltage sits in range. Wire it to a PLC input or a lamp. You get a hardwired supply fault signal without extra hardware.
Q: Can this unit run on 230 V AC?
A: No. This variant takes 90 to 132 V AC only. For 230 V feeds, choose a different 1606-XL variant. Wrong input voltage will damage the unit.
Q: How much load can the 120% boost carry?
A: It gives 12 A for short peaks under +45 °C. Use it for contactor or motor inrush. Do not run continuous loads above 10 A.
Q: Should I set the output to 24 V or 24.5 V?
A: Set 24.5 V for most panels. It covers voltage drop on long cable runs. Stay within the load device input range before you adjust.
Q: How do I pick between new and refurbished stock?
A: This model is still active, so new stock is easy to source. Refurbished units suit budget spares. Confirm test data, DC OK function, and the 12-month warranty before ordering.
Contact Us
Email: info@oiltechcontrols.com
WhatsApp: +86 158 8020 0923
Copyright © 2026 Oiltech Controls Limited. https://www.oiltechcontrols.com/ All rights reserved.
All rights reserved.










Reviews