1606-XLS240F Allen-Bradley 1606-XL Series 48 V DC 240 W Switched-Mode Power Supply
The 1606-XLS240F is a DIN-rail switched-mode power supply from the Allen-Bradley Bulletin 1606-XL series. It delivers 48 V DC, 5 A, 240 W with 92% typical efficiency. A 50% power reserve supports short load peaks. The unit suits machine builders, panel integrators, and MRO teams who need a stable DC bus in a compact housing. It carries UL 60950-1, cUL, and CE approvals. No communication interface is fitted, so commissioning stays simple and deterministic.
Why Buy From Oiltech Controls?
- More than 15 years of hands-on industrial automation spare parts work
- Worldwide shipping through FedEx, UPS, and DHL
- Tested industrial surplus and refurbished units available on request
- 12-month warranty on every order
- Technical verification before dispatch, including label and firmware checks
- Support for obsolete and legacy control systems
Questions go to info@oiltechcontrols.com or +86 158 8020 0923 on WhatsApp.
Technical Specifications
| Brand | Allen-Bradley |
| Model | 1606-XLS240F |
| Series | Bulletin 1606-XL, 1606-XLS Performance line |
| Module type | Switched-mode power supply, single or DC input |
| Input voltage | AC 100…240 V / DC 110…150 V |
| Output voltage | DC 48 V nominal, adjustable 48…56 V |
| Output current | 5 A nominal, 5…4.3 A range |
| Rated power | 240 W |
| Efficiency | 92.0% typical |
| Power losses | 20.9 W typical |
| Power reserve | 50% |
| Ripple and noise | 100 mVpp maximum |
| Power factor | 0.92 typical |
| Derating | 6 W/°C from +60 to +70 °C |
| Operating temperature | -25…+70 °C |
| Storage temperature | -40…+85 °C, non-operating |
| Protection rating | IP20 |
| Dimensions (H×W×D) | 124×60×117 mm |
| Weight | 0.90 kg |
| Communication | None, no built-in ports or protocols |
| Status signal | DC OK LED and DC OK relay contact |
| Humidity | Not published by manufacturer in 1606-TD002 |
| Lifecycle | Active on the official Rockwell page, verified 2026-10 |
Installation Guide
- Snap the unit onto a standard DIN rail. Leave free air above and below.
- Use spring clamp terminals for input, output, and relay wiring.
- Keep AC input and DC output cables physically separated.
- Set the output trim to the load requirement within 48…56 V.
- Check the DC OK LED after power-up. Wire the relay contact to a PLC input if needed.
- Respect derating above +60 °C. Do not block the ventilation slots.
Commissioning and Maintenance
Commissioning is fast. Apply input voltage, confirm the DC OK indicator, then measure output at the terminals. No software or protocol setup is required. Maintenance is limited to periodic checks of terminal torque, dust on the housing, and output voltage drift. Replace the unit if ripple exceeds 100 mVpp under rated load.
Diagnostics
The DC OK relay contact gives a hard-wired health signal to the control system. The front LED shows output status at a glance. Combined with measured output voltage, these two indicators cover most fault cases: input loss, overload, and output deviation. The 50% power reserve helps ride through motor start and capacitive load peaks without shutdown.
Compatibility Notes
- Fits standard 35 mm DIN rail inside 1606-XL series panels.
- Pin-compatible with other 1606-XLS single-output units in the same power class.
- Suits 48 V DC loads: sensors, relays, valve islands, and small drives.
- No fieldbus or software dependency, so it drops into existing cabinets without reconfiguration.
Approvals and Certifications
UL 60950-1, cUL, and CE marking, per the official Bulletin 1606 series standard. IP20 protection rating per the XLS series product page.
Packing List
- 1 × 1606-XLS240F power supply unit
- 1 × protective shipping carton
- Technical documentation on request
Warranty: 12 months. Shipping by FedEx, UPS, or DHL.
Typical Applications
- Machine control panels with 48 V DC actuators and sensors
- Process skids needing a regulated DC bus with status feedback
- Retrofit projects where an obsolete supply must be replaced
- Material handling and packaging lines with peak load demand
- Test benches and lab racks requiring low ripple
FAQ
Does the 1606-XLS240F have a communication port?
No. It has no built-in ports or protocols. Status comes from the DC OK LED and relay contact.
Can I adjust the output voltage?
Yes. The range is 48…56 V DC.
What happens above 60 °C?
Output derates by 6 W/°C up to +70 °C.
Is the unit still active?
Yes. It is active on the official Rockwell page, verified 2026-10.
What is the warranty and shipping method?
12-month warranty. Ships by FedEx, UPS, or DHL.
How do I confirm compatibility?
Email info@oiltechcontrols.com or message +86 158 8020 0923 on WhatsApp before ordering.
Copyright © 2026 Oiltech Controls Limited. All rights reserved.
Original Source: https://www.oiltechcontrols.com/









Reviews
There are no reviews yet.