1734-IB4 Allen-Bradley POINT I/O Digital DC Sinking Input Module, 4 Channels, 24VDC
1734-IB4 is a Allen-Bradley POINT I/O digital DC sinking input module. It has 4 input channels. Moreover, it works with 12/24VDC voltage category. This module fits distributed I/O architecture. Use it with any POINT I/O communication adapter and POINTBlock I/O modules. In addition, power dissipation is 1 W. Input current is 5 mA. It mounts on DIN rail. As a result, it saves panel space. It suits PLC-based systems that need compact, low-density I/O.
Technical Specifications
| Brand | Allen-Bradley |
| Model / Catalog No. | 1734-IB4 |
| Series | POINT I/O |
| Module Type | Digital DC Sinking Input Module |
| Inputs | 4 sinking input channels |
| Input Voltage | 24VDC nominal; field power 10–28.8VDC |
| Input Current | 5 mA maximum |
| On-State Voltage | 10VDC min; 24VDC nominal; 28.8VDC max |
| On-State Current | 2 mA min; 4 mA nominal; 5 mA max |
| Off-State Voltage | 5VDC maximum |
| Off-State Current | 1.5 mA minimum |
| Input Impedance | 3.6 kΩ nominal; 4.7 kΩ maximum |
| Input Filter Time | 0.5 ms hardware plus 0–63 ms user-selectable |
| POINTBus Current | 75 mA at 5VDC |
| Power Dissipation | 1 W; 3.4 BTU/hour |
| Isolation Voltage | 50V continuous |
| Dimensions | 56 x 12 x 75.5 mm (2.2 x 0.47 x 2.97 in.) |
| Weight | 31.8 g (1.12 oz) |
| Enclosure Rating | None (open-style) |
| Keyswitch Position | 1 |
| UPC | 10612598205223 |
| Indicators | 4 yellow input status LEDs; module and network status LEDs |
| Wiring Support | 2-wire or 3-wire input signals |
Measurement range: field power 10–28.8VDC. Frequency response: input filter 0.5 ms hardware plus 0–63 ms selectable. Sensitivity: on-state current from 2 mA. Linearity: digital input, so no analog linearity spec applies. Resolution: 1-bit per channel. Temperature range: use within the cabinet rating of the POINT I/O system. Environmental tolerance: open-style enclosure, so install in a protected panel. Noise immunity: 50V continuous isolation supports stable signals in industrial panels.
Installation Guide
- Mount on zinc plate, yellow chromate steel DIN rail. Avoid aluminum or plastic rail. These may corrode or oxidize. Poor conductors can cause bad grounding.
- Fix the DIN rail to the panel about every 200 mm (7.8 in.). Use suitable anchors.
- Install the module with keyswitch position 1.
- Wire all cables to the Removable Terminal Block (RTB) at the bottom.
- Use a 1734 POINT I/O communication adapter. The adapter supplies the network interface and POINTBus power.
- Keep the panel closed and clean. The module has an open-style rating.
Commissioning and Maintenance
Check the module status LED. It shows normal operation, recoverable fault, unrecoverable fault, or self-test mode. Then check the network status LED. It shows online, critical link failure, or communication fault. Also check the input LEDs. They show if input 0, 1, 2, or 3 is active. Write the node address on the front panel writable area. Set the input filter time from 0 to 63 ms as needed. Keep spare RTBs on hand for fast service.
Compatibility
1734-IB4 works with any 1734 POINT I/O communication adapter. It also works with POINTBlock I/O modules. In addition, it supports 2-wire and 3-wire input signals. Local I/O data maps to the host controller over the selected network. Therefore, it fits PLC-based distributed I/O systems.
Diagnostics
Front LEDs give fast fault finding. The module status LED reports recoverable and unrecoverable faults. Meanwhile, the network status LED reports link and communication faults. The four input LEDs show channel state at a glance. As a result, this design cuts downtime and speeds up troubleshooting.
Typical Applications
- Distributed I/O panels for PLC systems
- Discrete sensor and switch input collection
- Compact machine control cabinets
- Retrofit and expansion of POINT I/O networks
- Obsolete control system support
Why Buy From Oiltech Controls?
- 15+ years in industrial automation spare parts
- Worldwide shipping support
- Tested industrial surplus and refurbished options
- 12-month warranty
- Technical check before every shipment
- Support for obsolete control systems
Packing List and Warranty
Packing list: 1 x 1734-IB4 module. The removable terminal block is included only if shown in the listing photos. Warranty: 12 months from delivery. The warranty covers defects in materials and workmanship. However, it does not cover misuse, wrong wiring, or damage from improper installation.
Shipping
We ship by FedEx, UPS, and DHL. You get a tracking number after dispatch. Packing is secure for industrial electronics.
Certifications
The 1734-IB4 is a Rockwell Automation / Allen-Bradley product. It carries the manufacturer approvals for the 1734 POINT I/O family. Check the product label for the exact approval marks on your unit. Contact us for compliance documents.
FAQ
- Q: How many inputs does the 1734-IB4 have?
A: Four sinking input channels. - Q: What voltage does it use?
A: 24VDC nominal, with field power from 10 to 28.8VDC. - Q: Does it need a communication adapter?
A: Yes. Use a 1734 POINT I/O adapter. - Q: What is the input current?
A: 5 mA maximum. - Q: How do I set the filter time?
A: Use the 0 to 63 ms user-selectable setting. - Q: What is the warranty?
A: 12 months.
Contact Us
Email: info@oiltechcontrols.com
Phone / WhatsApp: +86 158 8020 0923
Copyright © 2026 Oiltech Controls Limited. All rights reserved.
Original Source: https://www.oiltechcontrols.com/
All rights reserved.