1734-IB8SK Allen-Bradley POINT Guard I/O Safety Input Module, Conformally Coated
The 1734-IB8SK is an Allen-Bradley POINT Guard I/O safety discrete input module. It provides eight sinking safety inputs and four pulse test outputs. A conformal coating protects the board in corrosive and hazardous areas. The module distributes safety I/O along GuardLogix, Compact GuardLogix and Smart Guard controllers. It meets SIL 3/4 and Cat. 3/4 requirements. Engineers specify the 1734-IB8SK when a standard POINT Guard module cannot survive the plant environment.
Key Specifications
- Inputs: 8 discrete safety channels, sinking configuration.
- Input voltage: 18-30 VDC operating range.
- Input type: Type 3 per IEC 61131-2.
- Min on-state current: 3.3 mA.
- Max off-state current: 1.3 mA.
- Input reaction time: below 16.2 ms.
- Pulse test outputs: 4 channels, current sourcing.
- Pulse output current: 0.7 A per channel, 2.8 A per module at 40 °C.
- Safety rating: SIL 3/4, Cat. 3 and 4.
- Coating: conformal, factory applied.
Wiring and Configuration Notes
- Supports single channel and dual channel operation.
- On delay and off delay set per channel in software.
- Pulse test sources: T0, T1M, T2, T3M.
- Field devices wire to the 8-point terminal base.
- Verify off-state voltage stays below 5 VDC.
Compatibility and Diagnostics
- Works with GuardLogix, Compact GuardLogix and Smart Guard.
- Reports channel status and pulse test faults to the controller.
- Short circuit and cross fault detection on safety channels.
- Reaction time data supports safety validation reports.
Packing List and Shipping
- 1 x 1734-IB8SK module.
- Anti-static protective packaging.
- 12-month warranty from Oiltech Controls.
- Dispatch within 24-28 hours after order confirmation.
- Shipping by FedEx, UPS or DHL.
- Questions: info@oiltechcontrols.com or +86 158 8020 0923.
FAQ
Is the conformal coating visible on a used unit?
- Yes. A glossy film covers the board. Ask for close photos before you buy.
Can I use the 1734-IB8SK in a standard POINT I/O rack?
- No. It needs a GuardLogix-compatible adapter and a safety-rated terminal base.
What should I check when buying surplus stock?
- Ask for the date code, coating condition and pulse output test result.
Does the module need a separate fieldbus power supply?
- Not required. Backplane power is enough. A separate supply is optional.
How do I pick between single and dual channel wiring?
- Use dual channel for Cat. 3 or 4 loops. Single channel fits lower risk points.