6SL3244-0BB13-1FA0 | Siemens SINAMICS CU240E-2 PN-F Control Unit
The 6SL3244-0BB13-1FA0 is a SINAMICS control unit from Siemens. It combines PROFINET and EtherNet/IP communication on one board. Six standard digital inputs, one fail-safe digital input, two relay outputs and two analog channels cover common drive I/O needs. The unit supports V/f modes, sensorless vector control and encoderless torque control. It fits Power Modules in the SINAMICS G120 family.
Identity and Power
- Article No.: 6SL3244-0BB13-1FA0
- Brand: Siemens
- Series: SINAMICS G120 control unit
- Operating voltage: DC 24 V via Power Module
- External supply: DC 20–29 V
- Max. power consumption: 0.50 A
- Power loss: 5.50 W
Communication and I/O
- Protocols: PROFINET, EtherNet/IP
- Standard digital inputs: 6; 0→1 at 11 V, 1→0 at 5 V
- Fail-safe digital input: 1 (uses 2 × standard DI)
- Relay outputs: 2, changeover type
- Analog/digital inputs: 2, differential
- Analog outputs: 2, non-isolated
Control Modes
- V/f linear, square-law and parameterizable
- V/f with flux current control (FCC)
- V/f ECO linear and square-law
- Sensorless vector control
- Encoderless torque control
- No sensor vector or encoder torque control
Environment and Mechanical Data
- Operating temperature: −10 to 55 °C
- Storage temperature: −40 to 70 °C
- Max. operating humidity: 95%
- Signal cable: 0.05–1.50 mm² (AWG 28–16)
- Protection: IP20 / UL open type
- Net weight: 0.49 kg
- Dimensions (W × H × D): 73 × 199 × 46 mm
Standards
- CE, UL, cUL, RCM, SEMI F47
- CE marking: Low-voltage directive 2014/35/EC
Compatible Equipment
- SINAMICS G120 Power Modules
- PROFINET drive networks
- EtherNet/IP line controllers
- Panels needing fail-safe stop functions
- Pump, fan and conveyor drive retrofits
FAQ
Does CU240E-2 PN-F run both PROFINET and EtherNet/IP at once?
No. Choose one protocol at commissioning. The hardware supports both. Only one active fieldbus stack runs.
What does the fail-safe input require?
It uses two standard DI channels for redundancy. Wire both per the manual. Test the safe stop function before release.
Can I reuse my existing G120 Power Module?
Check frame size and firmware compatibility first. Match the control unit version to the Power Module. Verify parameter backup before swap.
Why do my analog signals drift?
Check shield bonding to PE. Keep analog cable away from motor cables. Use differential inputs for long runs.
What should I record before replacing a unit?
Save parameters and firmware version. Note fieldbus address and I/O mapping. Reload and verify after fitting.