F3XC08-0N Yokogawa No-Voltage Contact Input Module – 8-Point Transformer-Isolated Input
The Yokogawa F3XC08-0N is an 8-point no-voltage contact input module for Yokogawa FA-M3 and F3 series control systems. It uses transformer isolation for reliable signal separation in electrically noisy plants. Each input point supports independent interrupt setting. The module suits high-density discrete signal acquisition in process and factory automation.
Why Buy From Oiltech Controls?
- More than 15 years of hands-on industrial automation spare parts sourcing
- Worldwide shipping through FedEx, UPS, and DHL
- Tested industrial surplus and refurbished options available
- 12-month warranty on every module we supply
- Technical verification before every shipment
- Continued support for obsolete and legacy control systems
Technical Specifications
| Brand | Yokogawa |
| Model | F3XC08-0N |
| Series | F3 Series (FA-M3 compatible) |
| Module Type | No-Voltage Contact Input Module |
| Input Type | No-voltage contact (dry contact) |
| Number of Inputs | 8 points, 8 points/common |
| Isolation Method | Transformer isolation |
| Contact Ratings | 5 V DC min., 20 mA max. |
| ON Resistance | 200 Ω max. |
| OFF Resistance | 100 kΩ min. |
| Simultaneous ON Ratio | 100% of inputs |
| Input Response Time | Selectable 2.0 ms max. or 17 ms (OFF to ON and ON to OFF) |
| Interrupt | Configurable per input point |
| External Connection | 10-point terminal block, M3.5 screw |
| Current Consumption | 75 mA |
| Weight | 140 g |
| Operating Temperature | 0 to 55°C |
| Storage Temperature | -20°C to 75°C |
| Operating Humidity | 10 to 90% RH, non-condensing |
| Storage Humidity | 10 to 90% RH, non-condensing |
| Atmosphere | Free of corrosive gases, flammable gases, and heavy dust |
Key Performance Data
- Measurement Range: Dry contact signals, 5 V DC min. to 20 mA max.
- Frequency Response: Fast mode 2.0 ms max., slow mode 17 ms
- Sensitivity: Detects contact resistance up to 200 Ω
- Linearity: Digital contact detection, no analog drift
- Resolution: 1 bit per input point, 8 points total
- Temperature Range: 0 to 55°C operating
- Environmental Resistance: Handles 10 to 90% RH and clean plant air
- Interference Immunity: Transformer isolation blocks ground loops and common-mode noise
Installation Guide
- Mount the module in a Yokogawa F3 series base unit slot.
- Wire field contacts to the 10-point M3.5 screw terminal block.
- Keep input cables short and away from high-power lines.
- Set response time per channel in the engineering tool.
- Enable interrupts only on points that need fast event capture.
- Confirm 75 mA current draw fits the base unit power budget.
Commissioning and Maintenance
- Check ON/OFF state per point in the monitor window.
- Measure contact resistance during routine shutdowns.
- Replace contacts above 200 Ω to avoid false OFF states.
- Clean terminals only with dry, lint-free tools.
- No calibration is needed for digital contact inputs.
Compatibility
The F3XC08-0N fits Yokogawa F3 series I/O slots and works with FA-M3 style architectures. It accepts standard dry contacts from pushbuttons, relays, limit switches, and auxiliary contacts. The module pairs with Yokogawa power supply and CPU modules of the same series.
Certifications
This module follows Yokogawa factory quality standards. Contact us for the certificate of conformity and test report for your build date.
Packing List
- 1 x Yokogawa F3XC08-0N module
- 1 x Anti-static protective bag
- 1 x Test report
- 1 x Protective carton with foam inserts
Warranty and Shipping
All modules carry a 12-month warranty. We ship worldwide by FedEx, UPS, and DHL. Orders placed before 15:00 CST usually ship the same day. Tracking numbers arrive by email after dispatch.
Typical Applications
- Pushbutton and selector switch input in control panels
- Relay and auxiliary contact monitoring
- Limit switch and position feedback on machines
- Alarm and interlock contact scanning
- Legacy FA-M3 system expansion and retrofit
Diagnostic Capability
Each point supports independent interrupt setting for fast event detection. The module reports ON/OFF state per channel in the engineering tool. Fast and slow response modes help separate real contact chatter from valid signals. Line monitoring through the CPU helps locate open or stuck contacts.
FAQ
Q: What input signal does this module accept?
A: It accepts dry no-voltage contacts only. Do not apply external voltage to the input terminals.
Q: How many inputs share one common?
A: All 8 inputs share one common point.
Q: Can I set different response times per channel?
A: Yes. Each channel selects 2.0 ms max. or 17 ms.
Q: Is the module isolated from the backplane?
A: Yes. Transformer isolation separates the input side from the internal bus.
Q: Does it support interrupts?
A: Yes. Interrupt setting is available for each input point.
Q: What is the warranty?
A: 12 months from the date of delivery.
Contact Us
Email: info@oiltechcontrols.com
WhatsApp: +86 158 8020 0923
Copyright © 2026 Oiltech Controls Limited. All rights reserved.
Original Source: https://www.oiltechcontrols.com/
All rights reserved.










Reviews
There are no reviews yet.