F3XD32-4F | Yokogawa | DC Input Module – 32-Point, 12 V DC, Photocoupler Isolation
F3XD32-4F is a Yokogawa DC input module for industrial control systems. It provides 32 input points with photocoupler isolation. The module accepts 12 V DC sink/source signals. It suits high-density panels and legacy Yokogawa architectures. Each point draws only 4.1 mA. The module supports 8 points per common and a 40-pin connector. Use it where fast, reliable DC input sensing is required.
Technical Specifications
| Brand | Yokogawa |
|---|---|
| Model | F3XD32-4F |
| Input Type | DC voltage, sink/source |
| Number of Inputs | 32 points |
| Isolation | Photocoupler isolation |
| Rated Input Voltage | 12 V DC |
| Rated Input Current | 4.1 mA/point at 12 V DC |
| Operating Voltage Range | 10.2 – 13.2 V DC |
| ON Voltage / Current | 8.0 V DC min. / 2.6 mA min. |
| OFF Voltage / Current | 3.4 V DC max. / 1.0 mA max. |
| Input Response Time (OFF→ON) | Selectable: Always (0 μs), 62.5 μs, 250 μs, 1 ms, 16 ms |
| Input Response Time (ON→OFF) | Selectable: Always (0 μs), 62.5 μs, 250 μs, 1 ms, 16 ms |
| Simultaneous ON Ratio | 100% |
| External Connection | One 40-pin connector |
| Common Points | 8 points/common |
| Interrupt | Configurable per input point |
| Current Consumption | 75 mA (5 V DC) |
| Weight | 120 g |
| Operating Temperature | 0 to 55 °C |
| Storage Temperature | -20 to 75 °C |
| Operating Humidity | 10 to 90% RH, non-condensing |
| Storage Humidity | 10 to 90% RH, non-condensing |
| Atmosphere | No corrosive gases, flammable gases, or heavy dust |
Key performance note: The module delivers fast response with selectable sampling down to 62.5 μs. It maintains 100% simultaneous ON ratio. Isolation protects the backplane from field transients. The 32-point density saves panel space. The 8-point common simplifies wiring and fault isolation.
Installation Guide
- Mount the module in a Yokogawa rack or compatible enclosure.
- Confirm 12 V DC field power before wiring.
- Use the 40-pin connector for input signals. Follow pin assignments in the manual.
- Keep common groups isolated. Each group handles up to 8 points.
- Respect the 10.2 – 13.2 V DC operating range. Do not exceed 13.2 V DC.
- Allow air flow. Keep ambient temperature within 0 to 55 °C.
- Avoid corrosive gases, flammable gases, and heavy dust.
Commissioning and Maintenance Convenience
- Set input response time per channel: Always, 62.5 μs, 250 μs, 1 ms, or 16 ms.
- Enable per-point interrupts for event-driven logic.
- Verify ON state at 8.0 V DC min. / 2.6 mA min.
- Verify OFF state at 3.4 V DC max. / 1.0 mA max.
- Check current draw: 75 mA at 5 V DC.
- Inspect the 40-pin connector for secure seating during routine checks.
- Log module temperature. Keep within the stated operating range.
Compatibility and Diagnostics
The F3XD32-4F fits Yokogawa F3 series racks and systems that accept the 40-pin input module format. It supports sink or source field wiring. Use it to replace failed modules in existing installations. The photocoupler isolation and per-point interrupt capability help engineers diagnose field wiring faults. For compatibility confirmation, contact info@oiltechcontrols.com.
Typical Applications
- Discrete sensor input for Yokogawa DCS or PLC systems.
- High-density panels with 32-point DC input needs.
- Legacy control systems requiring 12 V DC input modules.
- Pulse or event capture using selectable 62.5 μs sampling.
- Interrupt-driven logic for fast machine signals.
Why Buy From Oiltech Controls?
- 15+ years in industrial automation spare parts.
- Global shipment support via FedEx, UPS, and DHL.
- Tested industrial surplus and refurbished options available.
- 12-month warranty on qualifying products.
- Technical verification before every shipment.
- Support for obsolete control systems and hard-to-find modules.
Packaging, Shipping, and Warranty
- Packaging: 1 × Yokogawa F3XD32-4F module. Anti-static bag and protective carton. Manual or pinout reference included when available.
- Shipping: FedEx, UPS, and DHL options. Tracking provided.
- Warranty: 12 months from shipment date. Covers functional defects under normal use.
- Certifications: Yokogawa industrial standards. Contact us for specific certification documents.
FAQ
Q: Is the F3XD32-4F a sink or source input module?
A: It supports both sink and source wiring for 12 V DC signals.
Q: How many inputs share a common?
A: 8 points per common. The module has 32 inputs total.
Q: Can I select different response times per channel?
A: Yes. Input sampling is selectable per module setting: Always (0 μs), 62.5 μs, 250 μs, 1 ms, and 16 ms.
Q: Does the module support interrupts?
A: Yes. Interrupts are configurable for each input point.
Q: What is the current draw?
A: The module draws 75 mA at 5 V DC.
Q: How do I verify a field input is ON?
A: Measure at least 8.0 V DC and 2.6 mA at the input point.
Q: What shipping carriers do you use?
A: We ship with FedEx, UPS, and DHL.
Q: Is a warranty included?
A: Yes. A 12-month warranty applies to qualifying products.
Contact Information
Email: info@oiltechcontrols.com
Phone / WhatsApp: +86 158 8020 0923
We support technical verification before shipment. Send your system details for compatibility checks. For urgent needs, reach us via WhatsApp.
Copyright © 2026 Oiltech Controls Limited. All rights reserved.
Original Source: https://www.oiltechcontrols.com/
All rights reserved.










Reviews