Product Brief – IS200TBTCH1B
IS200TBTCH1B is a thermocouple input terminal board from GE Mark VI Speedtronic series. It handles 24 thermocouple channels (E, J, K, S, T) and supports TMR configurations with 6 DC connectors. Designed for turbine temperature monitoring in simplex and redundant systems.
Core Specifications
- Part Number: IS200TBTCH1B
- Manufacturer: General Electric (GE)
- Series: Mark VI Speedtronic
- Product Type: Thermocouple Input Terminal Board
- Channels: 24
- Thermocouple Types: E, J, K, S, T (B, N, R with PTCCH2 in Mark VIe)
- Input Span: -8 mV to +45 mV
- Operating Temp: 0 to +45 °C
- Dimensions: 15.9 x 17.8 cm
- Connectors: Six DC-type (for TMR); two barrier terminal blocks (48 terminals)
- Country of Origin: USA
- Manual Reference: GEH-6421M
Hardware & Functional Features
- Two long terminal blocks – 48 silver cube terminals (numbered 1–48).
- Two jack ports labeled JA1 and JB1.
- Rows of blue resistors and silver capacitors span the board length.
- Conformal coating for PCB protection.
- Shield terminal strip on each block for chassis ground connection.
- Accepts wires up to #12 AWG.
Installation & Operation
- Wire thermocouples directly to the two removable I/O terminal blocks.
- Each block secured with two screws; terminals accept up to #12 AWG.
- For Mark VI systems, cable J-type connectors to I/O processors in VME rack.
- Supports grounded or ungrounded thermocouples up to 300 m away (450 Ω max loop resistance).
- High-frequency noise suppression plus two cold junction (CJ) references.
- I/O processor handles A/D conversion and linearization.
System Configurations – Suitable Equipment
- Mark VI Simplex: TBTCH1C + one VTCC processor (two cables).
- Mark VI TMR: IS200TBTCH1B + three VTCC boards (six cables).
- Mark VIe Simplex: two PTCC packs plugged into TBTC for 24 inputs.
- Mark VIe TMR: TBTCH1B with fan-out to three J-connectors.
- Capacity: Mark VI = 24 inputs; Mark VIe = 12 inputs per pack.
Oiltech Controls’s Insight
- Choose TBTCH1B for TMR applications – it has six DC connectors vs two on the simplex version.
- For Mark VIe, B/N/R thermocouples require PTCCH2 – verify compatibility.
- Always check cable resistance: max 450 Ω two-way for accurate readings.
- Use shielded thermocouple wires and connect shield to chassis ground to reduce noise.
- The conformal coating enhances durability in harsh turbine environments.
5 Professional FAQs (with experience & selection guide)
- Q1: What is the difference between TBTCH1B and TBTCH1C?
A: TBTCH1B is for TMR systems with six DC connectors; TBTCH1C is for simplex with two connectors. Select based on your system redundancy requirement. - Q2: Can I use this board with B, N, or R thermocouples?
A: Yes, but only in Mark VIe systems when paired with PTCCH2. In standard Mark VI, only E, J, K, S, T are supported. - Q3: What is the maximum distance between thermocouple and board?
A: Up to 300 meters (984 ft) with total two-way cable resistance below 450 Ω. Longer runs may cause measurement errors. - Q4: How do I handle noise suppression for thermocouple inputs?
A: The board includes high-frequency noise filters. Always ground shields at the chassis ground terminal strip on each block. - Q5: Is this board compatible with Mark VIe systems?
A: Yes, when used with PTCC I/O packs. For TMR, use TBTCH1B with three PTCC packs; for simplex, use two PTCC packs with TBTCH1C.
Why Buy From Oiltech Controls?
- Over 15 years in industrial automation spare parts.
- Global shipping via FedEx, UPS, DHL – 24~28 hour dispatch.
- Every unit tested – surplus or refurbished options available.
- 12-month warranty on all products.
- Technical verification performed before shipment.
- Expert support for obsolete control systems.
Contact: info@oiltechcontrols.com |
+86 158 8020 0923 (WhatsApp)
Shipping: FedEx, UPS, DHL – worldwide express. In stock, ships within 24~28 hours.
Copyright © 2026 Oiltech Controls Limited. https://www.oiltechcontrols.com/ All rights reserved.