Honeywell Searchpoint Optima Plus Gas Detector
The 2108B2001N is a premium infrared gas detector. It finds flammable hydrocarbon gases in dangerous areas. This detector works in extreme temperatures. It gives fast and accurate readings to keep people safe.
Why Choose This Gas Detector
- Proven Reliability: Over 100,000 units installed worldwide.
- Extreme Environment Ready: Works from -40°C to +65°C.
- Fast Response: Detects gas leaks in under 4 seconds.
- Safety Certified: ATEX, IECEx, UL/CSA approvals for hazardous areas.
- Smart Communication: 4-20mA output with HART or Modbus options.
Detection Performance
- Detection Principle: Point Infrared (IR) Absorption
- Target Gases: Hydrocarbons (Methane, Ethylene, etc.)
- Measuring Range: 0-100% LEL (Lower Explosive Limit)
- Response Time: T50 < 3 sec, T90 < 4 sec (for methane)
- Accuracy: Baseline ±1% FSD, 50% FSD ±2% FSD
- Repeatability: Better than ±2% FSD at 50% FSD
- Linearity: Less than 5% FSD
- Long-Term Stability: ≤ ±2% FSD (methane baseline)
- Temperature Drift: ≤ ±2% FSD (baseline), ≤0.131% FSD/°C (methane at 50% FSD)
- Pressure Effect: 0.1% of reading per mbar
Physical & Electrical Specifications
- Housing Material: 316 Stainless Steel
- Weight: 1.6 kg (3.5 lbs)
- Enclosure Protection: IP66/67 (Dust tight, protected against water jets/immersion)
- Power Supply: 18-32V DC (24V DC nominal)
- Power Consumption: < 4.5 Watts maximum
- Signal Output: 4-20mA, auto-sensing sink or source
- Digital Options: HART (over 4-20mA) or Modbus RS485 via optional module
- Output Signals:
- Inhibit: 1-3mA (default 2mA)
- Warning: 0-6mA (default 3mA)
- Fault: 0mA (adjustable to 1mA for HART units)
- Over Range: 20-21.5mA (default 21mA)
Environmental & Safety Ratings
- Operating Temperature: -40°C to +65°C (-40°F to +149°F)
- ATEX Certification: II 2 GD Ex d IIC Gb Ex tb IIIC Db T96°C
- IECEx Certification: Ex d IIC tb IIIC T86°C / T96°C
- UL/CSA Certification: Class I, Div 1, Groups B, C, D
- Functional Safety: IEC 61508 SIL 2 (Assessed by TÜV)
- EMC Compliance: EN 50270:2006
- Performance Standard: EN 60079-29-1
Package & Support Information
- The detector comes new in original factory packaging.
- Includes necessary documentation and calibration data.
- Backed by a 12-month manufacturer warranty.
- We ship globally via FedEx, UPS, and DHL express services.
- Tracking information is provided for all orders.
Frequently Asked Questions
Q: What does “LEL” mean in the measuring range?
A: LEL means Lower Explosive Limit. 100% LEL is the lowest concentration of gas in air that can create an explosion.
Q: Can this detector be used for ethylene gas?
A: Yes, the Searchpoint Optima Plus can be calibrated for ethylene. Note that accuracy specifications differ slightly from methane.
Q: How often does the detector need calibration?
A: Recommended calibration interval is typically every 6-12 months, depending on application, regulations, and environmental conditions.
Q: What is the difference between IP66 and IP67 ratings?
A: IP66 protects against powerful water jets. IP67 protects against temporary immersion in water up to 1 meter for 30 minutes. This unit meets both.
Q: From field experience, what affects sensor performance most?
A> Window contamination is the main issue. Keep the optical window clean. Consider protective covers or scheduled cleaning in dirty environments.
Contact Information: For product inquiries: info@oiltechcontrols.com or WhatsApp +86 158 8020 0923.
Copyright © 2025 Oiltech Controls Limited. All rights reserved.
Original Source: https://www.oiltechcontrols.com/
Partner: PLCDCS HUB Limited https://plcdcshub.com/. All rights reserved.






David Martinez –
Our facility urgently needed a replacement detector — this Searchpoint Optima Plus arrived faster than expected. The unit is clearly new and authentic, with full hazardous-area certification. Once installed, it detected a minor methane leak in under 4 seconds, allowing us to shut down safely. Extremely professional service and top-tier product reliability.