KEB Combivert F5 – 14F5A1E-3A0A Frequency Inverter
The 14F5A1E-3A0A is a robust frequency inverter from KEB Combivert F5 series. It delivers 11 kVA power for 7.5 kW AC/DC motors. This unit operates on 400V 3-phase input. It is a controlled drive with integrated brake transistor (GTR7) and air cooling. Ideal for demanding industrial speed control applications.
Core Technical Specifications
- Model: 14F5A1E-3A0A (KEB Combivert F5).
- Rated power: 11 kVA / 7.5 kW (2/4P motor, 50/60 Hz).
- Input voltage: 305 to 528 V AC, 3-phase.
- Output voltage: 0 to Uin (variable).
- Rated output current: 16.5 A (short-time limit 29.7 A).
- Output frequency range: 0 to 599 Hz (max).
- Switching frequency: 8 kHz.
- Protection class: IP20 (cabinet installation).
- Dimensions (WxHxD): 130 x 290 x 208 mm.
- Brake transistor: GTR7 integrated.
- Cooling: Forced air cooling (heatsink).
Oiltech Controls’s Insight – Application Notes
- The F5 series is known for its rugged construction and reliable torque control.
- We recommend this drive for conveyor systems, fans, and pumps.
- Its 599 Hz output makes it suitable for high-speed spindle applications.
- Brake transistor GTR7 allows dynamic braking without external module.
- IP20 design means it must be installed in a clean, dry control cabinet.
Typical Equipment & Systems
- Industrial conveyor belts and material handling systems.
- Centrifugal pumps and blowers in HVAC or process plants.
- Machine tool spindles requiring up to 599 Hz.
- Extruders and mixers with variable torque demands.
- Retrofit for older KEB drives or competitor units (e.g., Siemens, ABB).
Expert FAQ – Selection & Operation
- Q: Can this drive run a motor rated for 400V only?
Yes. The input range is 305-528V, so it works with 400V nominal systems. Set the motor parameters correctly in the F5 keypad. - Q: What is the maximum cable length to motor?
For 8 kHz switching frequency, keep motor cable under 50 m. For longer runs, reduce switching frequency to 4 kHz or add output filters. - Q: Do I need an external braking resistor?
Only if the internal GTR7 brake transistor is not sufficient for your deceleration energy. Check the duty cycle; for high-inertia loads, external resistor is recommended. - Q: Is the 14F5A1E-3A0A compatible with single-phase input?
No. This is a 3-phase only drive. Single-phase operation will cause undervoltage faults. - Q: How to reset a fault after overcurrent trip?
Press the STOP/RESET key on the keypad. If fault persists, check motor insulation and cable connections. We advise a megger test before restarting.
Why Buy From Oiltech Controls?
- 15+ years in industrial automation – we know drives inside out.
- Every unit, including surplus or refurbished, is tested before shipping.
- We support obsolete systems and can advise on compatible replacements.
- Global express shipping via FedEx, UPS, or DHL – dispatch within 24-28 hours.
- 12-month warranty gives you peace of mind.
Shipping, Warranty & Contact
- Dispatch time: 24-28 hours from order confirmation.
- Carriers: FedEx, UPS, DHL (tracked and insured).
- Warranty: 12 months against manufacturing defects.
- Technical inquiries: info@oiltechcontrols.com | +86 158 8020 0923 (WhatsApp).
Original Source: https://www.oiltechcontrols.com/
Copyright © 2026 Oiltech Controls Limited. All rights reserved.