Keyence SJ-E156H Bar-Type Static Eliminator – High-End Ionizer for Critical Processes
Model SJ-E156H from Keyence is a high-end bar-type static eliminator. It uses corona discharge with a shockless resistive coupling structure. The pulse AC method applies ±8000 V. This ionizer delivers stable ion balance through the Hi-Power I.C.C. method. It suits demanding industrial static control.
Technical Specifications
| Brand | Keyence |
| Model | SJ-E156H |
| Series | SJ-E series |
| Product Type | Bar-type static eliminator (high-end model) |
| Ion Generation | Corona discharge |
| Structure | Shockless resistive coupling type |
| Voltage Application | Pulse AC method, ±8000 V |
| Ion Balance Control | Hi-Power I.C.C. method |
| Ion Balance | ±30 V (at 300 mm or more, 0.2 MPa air pressure) |
| Installation Distance | 50 to 2000 mm |
| Number of Electrodes | 49 |
| Effective Length | 1620 mm (static elimination range at 50 mm) |
| Total Length | 1520 mm |
| Supply Voltage | 24 to 36 VDC ±10% |
| Current Consumption | 700 mA at 24 V, 500 mA at 36 V |
| Output Type | NPN open collector (ion level warning, condition warning, alarm output) |
| Control Input | Static elimination stop input (NPN open collector or contact point) |
| Control Output | NPN open collector, 100 mA maximum (40 VDC or less) |
| Air Connection Port | Rc 1/8 |
| Air Supply Pressure | 0.1 to 0.5 MPa (recommended 0.2 MPa) |
| Overvoltage Category | I |
| Pollution Degree | 2 |
| Operating Temperature | 0 to +40 °C |
| Relative Humidity | 35 to 85 % RH (no condensation) |
| Protection Rating | Not available |
| Weight | 1.75 kg |
| Electrode Probe Material | Tungsten |
| Main Body Material | ABS/PBT/PP/LCP/PPS/SPS/SUS |
| Communication | Remote control communication (no built-in ports, no expansion) |
Key performance notes: The SJ-E156H provides a wide installation distance of 50 to 2000 mm. It maintains ion balance within ±30 V. The 49 tungsten electrodes ensure uniform static elimination across a 1620 mm effective length. This bar-type ionizer handles high-speed lines and sensitive electronics.
Installation Guide
- Mount the bar at 50 to 2000 mm from the target surface.
- Use the Rc 1/8 air port. Set air pressure to 0.1 to 0.5 MPa (0.2 MPa recommended).
- Connect 24 to 36 VDC power. Observe polarity.
- Wire the NPN open collector outputs for alarm and warning signals.
- Keep the total length of 1520 mm in mind for mounting clearance.
- Do not exceed operating temperature of 0 to +40 °C.
Setup and Maintenance Convenience
The SJ-E156H supports remote control communication. No built-in ports are present, but remote signals allow external monitoring. The shockless resistive coupling design reduces risk during maintenance. Clean the tungsten electrodes with a soft brush. Check ion balance periodically. The Hi-Power I.C.C. method self-regulates to maintain performance. Replace the bar only when physical damage occurs.
Compatibility Notes
This ionizer works with Keyence SJ-E series controllers and power supplies. It accepts NPN open collector control inputs. The alarm output drives PLCs or indicators. No communication expansion is available. For legacy systems, use the static elimination stop input. The 24 to 36 VDC range fits common industrial power buses.
Certification Information
Overvoltage category I. Pollution degree 2. No specific protection rating is declared. The product is active and in production as of 2026-09. Confirm local electrical codes before installation.
Package Contents
- One Keyence SJ-E156H bar-type static eliminator
- Mounting hardware (as supplied by Keyence)
- Quick reference guide (if included by manufacturer)
Warranty and Shipping
12-month warranty covers defects in materials and workmanship. We ship via FedEx, UPS, and DHL. Tracking is provided. Contact us for expedited options.
Typical Applications
- Electronics assembly and PCB handling
- Film and sheet converting
- Packaging lines with high static
- Printing and coating processes
- Automotive parts transfer
- Medical device manufacturing
Diagnostic Capabilities
The SJ-E156H provides ion level warning, condition warning, and alarm output. These NPN open collector signals help you detect electrode contamination or abnormal discharge. Use the static elimination stop input for quick shutdown. Remote control communication allows basic status checks. This design supports preventive maintenance.
FAQ
Q: What is the ion balance?
A: ±30 V at 300 mm or more with 0.2 MPa air pressure.
Q: How many electrodes does it have?
A: 49 tungsten electrodes.
Q: What voltage does it use?
A: 24 to 36 VDC ±10%.
Q: Can I use it without air?
A: Air is recommended. Use 0.1 to 0.5 MPa.
Q: Does it have built-in communication ports?
A: No. It uses remote control communication only.
Why Buy From Oiltech Controls?
- 15+ years in industrial automation spare parts.
- Global shipment support with FedEx, UPS, DHL.
- Tested industrial surplus and refurbished options available.
- 12-month warranty on every eligible unit.
- Technical verification before shipment to confirm function.
- Support for obsolete control systems and legacy parts.
Inquiries: info@oiltechcontrols.com or +86 158 8020 0923 (WhatsApp).
Copyright © 2026 Oiltech Controls Limited. All rights reserved.
Original Source: https://www.oiltechcontrols.com/










Reviews
There are no reviews yet.