TC-PIL081 Honeywell Temperature Input Module (8-Points) for Industrial Control Systems
The TC-PIL081 is an 8-channel temperature input module from Honeywell. It accepts thermocouple and RTD signals. It fits Series 8 I/O systems and supports intrinsic safety for hazardous areas. Each channel group is configurable. The module delivers 16-bit resolution and fast 4 ms response. It suits process monitoring, burner management, and legacy DCS upgrades.
Why Buy From Oiltech Controls?
- More than 15 years of industrial automation spare parts experience
- Global shipment support through FedEx, UPS, and DHL
- Tested industrial surplus and refurbished options
- 12-month warranty on every module
- Technical verification before shipment
- Support for obsolete control systems
Contact us: info@oiltechcontrols.com or +86 158 8020 0923 (WhatsApp).
Technical Specifications
| Brand | Honeywell |
| Model | TC-PIL081 |
| Series | Series 8 Temperature Input Module |
| Module Type | 8-Point Temperature Input Module |
| Input Capacity | 8 channels, single common reference |
| Input Types | Thermocouple or RTD, configurable in groups 0–3 and 4–7 |
| Thermocouple Types | E, J, K, N, R, S, T, B, L, mV |
| TC Ranges | E: –270 to 1000 °C; J: –210 to 1200 °C; K: –270 to 1372 °C; N: –270 to 1300 °C; R/S: –50 to 1768 °C; T: –270 to 400 °C; mV: –40 to 100 mV |
| RTD Types | Pt100, Pt200, Ni100, Ni200, Ni120, Cu10, Ohm |
| RTD Ranges | Pt100 IEC: –200 to 870 °C; Pt100 JIS: –200 to 630 °C; Ni100: –60 to 250 °C; Cu10: –200 to 260 °C; Ohm: 0 to 500 ohms |
| Temperature Format | Celsius, Fahrenheit, Kelvin |
| Resolution | 16 Bits |
| Response Time | 4 ms |
| Accuracy | TC: ±0.5% (E, J, K, N), ±0.8% (R, S, T); RTD: 0.1% of span; Linearization: ±0.2 °C |
| Cold Junction | ±0.8 °C max at 25 °C; drift 100–300 ppm/°C |
| Filter | Configurable cutoff |
| Fault Detection | Lead breakage and short circuit, per channel group |
| Alarms | Overrange, underrange, cold junction alarm |
| Isolation | Input to backplane bus; input to power supply |
| Operating Temperature | –20 °C to 70 °C |
| Storage Temperature | –20 °C to 100 °C |
| Humidity | 95% max, non-condensing |
| Shock / Vibration | 15 g peak 11 ms; 2 g at 10–500 Hz (IEC 68-2-6) |
| Protection Class | IP20 (IP54 or better housing required in field) |
| Power Dissipation | 1.6 W; 0.19 PSU load |
| Weight | 0.247 kg (0.54 lb) |
| Dimensions | 76 x 94 x 46 mm (3.0 x 3.7 x 1.8 in) |
| Keyswitch Position | 2 |
Intrinsic Safety and Field Circuit Values
Inputs: Uo = 9 V, Io = 37 mA, Po = 83 mW. For EEx ia IIB: Lo 80 mH, Co 40 μF, Lo/Ro 1.7 mH/ohm. For EEx ia IIC: Lo 20 mH, Co 4.9 μF, Lo/Ro 0.4 mH/ohm. Internal CJC: Uo 9 V, Io 1 mA, Po 3 mW. External CJC: Uo 9 V, Io 38 mA, Po 86 mW.
Installation Guide
- Mount the module on the compatible Honeywell terminal base.
- Set the keyswitch to position 2.
- Use shielded multicore cable with one shield per channel.
- Keep channel isolation above 500 V.
- Confirm lead resistance stays below 10 ohms per lead.
- Install IP54 or better housing for field use.
Commissioning and Maintenance
Set input type and range per channel group. Choose 2-, 3-, or 4-wire RTD mode. Enable fault detection to catch broken leads or shorts. Use the overrange and underrange alarms for early warnings. The 4 ms response supports fast control loops. Oiltech Controls verifies each module before shipment. Contact info@oiltechcontrols.com for setup help.
Compatibility Notes
- Fits Honeywell Series 8 I/O terminal bases.
- Works with existing CJC reference elements.
- Supports external temperature compensation.
- Retrofits obsolete control systems with minimal changes.
Certifications
CENELEC (Europe): II (1) 2G EEx ia/ib IIB/IIC T4. Conforms to DIN EN 50014:1992, DIN EN 50020:1997, DIN EN 50284:1997. EMC per DIN EN 50081-2, DIN EN 50082-2, NAMUR NE 21. Certification mark: DMT 99 ATEX E-025 X. CE marked.
Typical Applications
- Process temperature monitoring in chemical plants
- Burner and furnace control
- Oil and gas safety loops
- Power plant sensor data acquisition
- Legacy DCS and PLC upgrades
Diagnostic Capabilities
Detects sensor lead breakage and short circuit per channel group. Provides overrange, underrange, and cold junction alarms. Fault detection is configurable. These features cut downtime and speed up troubleshooting.
Packing List and Warranty
- 1 x TC-PIL081 Temperature Input Module
- 12-month warranty
- Shipping via FedEx, UPS, or DHL
FAQ
Q: Which thermocouple types does TC-PIL081 support?
A: Types E, J, K, N, R, S, T, plus B, L, and mV input.
Q: Can I mix thermocouple and RTD inputs?
A: Yes. Groups 0–3 and 4–7 are configured separately.
Q: What is the response time?
A: 4 ms with 16-bit resolution.
Q: Is it suitable for hazardous areas?
A: Yes, with EEx ia/ib IIB/IIC T4 intrinsic safety ratings.
Q: How do I order?
A: Email info@oiltechcontrols.com or message +86 158 8020 0923 on WhatsApp.
Copyright © 2026 Oiltech Controls Limited. All rights reserved.
Original Source: https://www.oiltechcontrols.com/
All rights reserved.









Reviews