Module Snapshot
- Brand: Yokogawa
- Part Number: ADV169-P00
- Category: Digital I/O Module
- I/O Type: Digital input only
- Total Channels: 64 inputs
- Designed for stable large-scale signal collection.
Why Choose ADV169
- High channel count reduces rack space.
- Grouped isolation improves noise control.
- Simple wiring for field contacts.
- Low weight for easy handling.
- Proven Yokogawa reliability.
Input Signal Behavior
- Supports contact and voltage inputs.
- OFF contact detected at 100 kΩ or higher.
- ON contact detected at 200 Ω or lower.
- Minimum short-circuit current: 1.25 mA.
- Voltage OFF range up to 25 V DC.
Electrical Characteristics
- Input contact rating: 5 V DC.
- Handles 20 mA or more per contact.
- Total current draw up to 800 mA.
- Powered by system 5 V DC bus.
Speed and Stability
- Fast response time of 8 ms.
- Stable input reading for status signals.
- Suitable for continuous monitoring.
Isolation Design
- Common minus configuration.
- Isolation applied every 16 channels.
- Limits fault spread across inputs.
- Improves long-term system safety.
Suffix Structure
- Base Model
- ADV169 Digital input module
- Suffix Codes
- P Standard type
- 0 Fixed specification
- 0 Basic configuration
Mechanical and Wiring
- Approximate weight: 0.30 kg.
- Compact size fits dense racks.
- Uses dedicated KS9 cable.
- Clean layout reduces install errors.
System Compatibility
- Fully compatible with ST6 cards.
- Easy system replacement or expansion.
- Works with Yokogawa Centum VP systems.
Typical Use Cases
- Plant status monitoring.
- Switch and relay feedback.
- Alarm input collection.
- Large I/O count applications.
Warranty and Logistics
- 12-month warranty included.
- Tested before shipment.
- Worldwide delivery supported.
- Shipping via FedEx, UPS, or DHL.
Professional FAQ
- Is ADV169 suitable for high-density input systems?
- Yes. It supports 64 inputs in one module.
- Does this module support pushbutton counting?
- No. It is for status input only.
- How does common minus wiring help?
- It simplifies wiring and troubleshooting.
- When should I choose ADV169 over smaller modules?
- When cabinet space is limited.
- Is ST6 compatibility important?
- Yes. It ensures smooth system integration.
Contact Information
- Email: info@oiltechcontrols.com
- WhatsApp: +86 158 8020 0923
Copyright © 2026 Oiltech Controls Limited. All rights reserved.
Original Source:
https://www.oiltechcontrols.com/
Partner
PLCDCS HUB Limited. All rights reserved.










Reviews