ATV71HU22N4 – Schneider Electric Altivar 71 Variable Speed Drive
2.2 kW (3 HP) · 380-480 VAC · 3-phase · 0.1–599 Hz · Integrated EMC filter · Graphic terminal · 12-month warranty · Ships 24–28 hours via FedEx / UPS / DHL
Product Overview
- ATV71HU22N4 belongs to the Altivar 71 series – advanced variable speed drive.
- Rated motor power: 2.2 kW (3 HP) for 3-phase 380–480 VAC networks.
- Output frequency range: 0.1–599 Hz – covers broad speed control needs.
- Built-in EMC filter meets electromagnetic compatibility standards.
- Integrated graphic terminal simplifies setup, monitoring, and diagnostics.
- Designed for complex, high-power machines – asynchronous and synchronous motors.
Technical Specifications
- Manufacturer: Schneider Electric · Model: ATV71HU22N4 · Series: Altivar 71
- Motor power: 2.2 kW (3 HP) · Input voltage: 380–480 VAC -15…10% · Phase: 3-phase
- Output frequency: 0.1–599 Hz · Nominal switching freq: 4 kHz (adjustable 1–16 kHz)
- Line current: 7.1 A (480V) / 8.2 A (380V) · Apparent power: 5.4 kVA
- Nominal output current: 4.8 A (460V) / 5.8 A (380V) @ 4 kHz
- Max transient current: 8.7 A (60s) / 9.6 A (2s) · Prospective line Isc: 5 kA
- Motor control profiles: Sensorless flux vector (SFVC), flux vector with encoder (FVC), V/F ratio (2/5 points), ENA system
- Speed range: 1…100 (open-loop async) / 1…1000 (closed-loop async) / 1…50 (open-loop sync)
- Speed accuracy: ±0.01% (closed-loop) / ±10% slip (open-loop) · Torque accuracy: ±15% (open) / ±5% (closed)
- Transient overtorque: 170% for 60s · 220% for 2s · Braking torque: ≤150% with resistor
- Protection: Overvoltage, undervoltage, overcurrent, short-circuit, thermal, phase loss, overheating
- Communication: Modbus (RJ45) + CANopen (SUB-D 9) · Protocols: RTU, CANopen
- Ambient temp (operation): –10 to +50 °C · Storage: –25 to +70 °C
- IP degree: IP20 · Pollution degree: 2 · Vibration: 1 gn / 1.5 mm peak
- Weight: 3.0 kg (6.6 lbs) · Dimensions: 230 x 130 x 175 mm (H x W x D)
Installation & Mounting Guidelines
- Mounting: Vertical ±10° · With heat sink – ensure proper airflow.
- Electrical connection: Terminals: 2.5 mm² (AWG 14) for control; 4 mm² (AWG 10) for power.
- Tightening torque: 0.6 N·m (control) · 1.4 N·m (power).
- Max motor cable length: 50 m (shielded) · 100 m (unshielded).
- Use copper 70/90 °C cables per IEC; UL Type 1 kit optional for NEMA enclosures.
- Operating altitude: ≤1000 m without derating; derate 1% per 100 m up to 3000 m.
Commissioning, Maintenance & Diagnostics
- Graphic terminal provides real-time monitoring, parameter adjustment, and fault logging.
- Diagnostic LED (red) indicates drive voltage status.
- Protection: against overcurrent, short-circuit, overheating, phase loss, and DC bus overvoltage.
- Insulation resistance: >1 MΩ at 500 VDC for 1 minute.
- Braking: DC injection braking to standstill; optional braking resistor for higher torque.
- Maintenance: Periodic check of cooling fins and terminal torque; no routine calibration.
Compatibility & Typical Applications
- Compatible motors: Asynchronous (induction) and synchronous (permanent magnet) motors.
- Control modes: Sensorless flux vector, closed-loop flux vector with encoder, V/F ratio.
- Applications: Conveyors, hoists, cranes, extruders, mixers, pumps, fans, compressors.
- Option cards: Communication (Profibus DP, DeviceNet, EtherNet/IP, Modbus TCP), I/O extension, encoder interface, controller inside.
- Works with Schneider Electric Altivar 71 ecosystem – fully integrated.
Certifications & Standards
- Certifications: UL, CSA, NOM 117, GOST, C-tick, CE marked.
- Standards: EN 55011 Class A, EN 61800-3 (C2), EN/IEC 61800-5-1, IEC 60721-3-3.
- EMC immunity: Level 3 per IEC 61000-4-2, -3, -4, -5, -6; voltage dips per IEC 61000-4-11.
- Environmental: 5–95% RH non-condensing; shock 15 gn / 11 ms.
Frequently Asked Questions (Expert Insight)
- Q1: Can the ATV71HU22N4 run a synchronous motor without an encoder?
Yes. The drive supports open-loop vector control for synchronous motors (1…50 speed range). For high precision, add an encoder feedback card. - Q2: What is the real-world switching frequency limit with derating?
The nominal is 4 kHz; you can adjust up to 16 kHz, but derate output current above 4 kHz. For 2.2 kW, 8 kHz is typical without significant derating. - Q3: Which braking resistor do you recommend for hoisting applications?
Use a braking resistor rated for at least 150% torque. Schneider VW3A7 series resistors are compatible. Ensure resistor thermal protection is configured. - Q4: How do I integrate this drive with a PLC via Modbus?
Use the RJ45 port on the front (Modbus RTU, 4800–38.4 kbps). Set address (1–247) and parity. The drive supports standard read/write holding registers. - Q5: What is the maximum cable length for the encoder feedback?
For encoder interface cards, keep shielded cable under 100 m for reliable signal integrity. Use twisted-pair with proper grounding.
Why Buy From Oiltech Controls?
- Over 15 years in industrial automation spare parts – deep technical knowledge.
- Worldwide shipping via FedEx, UPS, DHL – fast and trackable.
- All units are tested (surplus/refurbished) with technical verification before dispatch.
- 12-month warranty covers manufacturing defects and performance issues.
- Expert support for obsolete control systems – we find alternatives.
Contact: info@oiltechcontrols.com · +86 158 8020 0923 (WhatsApp)
Shipping: 24–28 hour dispatch · Carriers: FedEx, UPS, DHL.
Copyright © 2026 Oiltech Controls Limited. https://www.oiltechcontrols.com/ All rights reserved.










Reviews
There are no reviews yet.