Bently Nevada 330104-00-04-10-02-CN Probe
Key Features
Measures 0.25 mm to 2.3 mm
Gives -1V to -17V output
Works in very cold to hot places. From -52°C to 177°C.
Has 1 meter cable
Uses M10x1 thread
40mm short case
China certifications
Model Numbers
330104: Armored probe
00: No unthreaded part
04: Case 40mm long
10: Cable 1 meter
02: ClickLoc connector
CN: China certified
Easy Setup
Mount with M10x1 thread
Set 1.27mm gap
Connect to Proximitor
Use -24V power
Works With
3300 XL systems
Compact machinery
China market systems
In The Box
Vibration probe
ClickLoc connector
Setup guide
Delivery & Help
Worldwide shipping
12 month warranty
24/7 support
Why choose the 0.4m short-cable version over standard 1m?
0.4m is for tight machinery enclosures where probe-to-proximitor spacing is under 0.6m; a 1m cable forces excess loops increasing capacitance, degrading EMI, and violating min bend radius. The short version keeps capacitance precise, extends FEP jacket life, and fits NEMA 4X junction boxes used on API 670 pumps.
- Part number coding: 4th digit = cable length x 100mm
- Capacitance target: ~120pF +/- 10pF (GFK-18799 §7)
- Min bend violations reduce jacket life >10 percent
How much extension can I add before hitting the 30m limit?
Subtract the built-in 0.4m from 30m — 29.6m capacity; however, short-cable probes pair almost always with single 330130-060 or 330130-070 cables rather than stacking. Always specify total loop length (probe cable plus all extensions) when ordering to avoid capacitance mismatch.
- Total loop <= 30 m (GFK-18799 §7)
- Capacitance tolerance +/-20pF keeps signal in spec (GFK-18799 §7)
Same vibration accuracy as 1m version?
Yes — 0.4m and 1m share the same PPS tip, 7.59 Ohm resistance, -50 to +175 C range, and -2 V to +18 V linear signal. Short cable has slightly lower loop capacitance (~100pF vs ~120pF for 1m plus 3m extension) which does not affect amplitude accuracy; only high-frequency response above 10 kHz shows 2-3 percent difference in extreme measurements.
- Resistance identical (GFK-17744 §2)
- Temp identical by cable length
- Amplitude accuracy +/-1% regardless of cable length
Frequently Asked Questions About the 330104-00-04-10-02-01
Can I splice a 330130 extension directly to this probe built-in cable?
No — splicing breaks capacitance balance and voids calibration. The probe ends in ClickLoc or SMA; mate via that connector. Cutting built-in cable destroys the probe; never splice PPS-insulated proximity cables.
Different proximitor gain than 1m version?
No. Gain is determined by probe family (330104 = 7.59 Ohm), not built-in cable length. Use 330180-50 under 10m loop or 330180-90 above 14m. Calibrate zero and span per factory sheet and actual total loop length.
Explore the Bently Nevada 3300 Series