Bently Nevada 330104-00-08-10-02-00 Proximity Probe
Key Features
Measure distance 0.25-2.3mm
Output voltage: -1V to -17V
Works from -52°C to +177°C
1 meter cable length
M10x1 mounting thread
Resistance: 7.59 ± 0.50 Ω
Industrial Uses
Compact machinery monitoring
Short-range vibration checks
Electric motor bearings
Small pump systems
Prevent unexpected failures
Model Codes ( 330104-00-08-10-02-00)
330104: Armored probe
00: 0mm unthreaded
08: 80mm case length
10: 1.0 meter cable
02: ClickLoc connector
00: No certifications
Package Includes
Vibration probe (1 unit)
ClickLoc connector
Installation guide
Shipping & Support
Global delivery: FedEx, UPS, DHL
12 month product warranty
24/7 technical help
Will this 330104 probe work with the 3500 monitoring rack?
Yes — both 3300 XL and 3500 racks accept any 330104 family 8mm probe paired with 330180 proximitor; no adapter needed because the -2 V to +18 V signal and ClickLoc connector are shared across platforms, but loop length caps at 30 m and 11mm probes (330701) require 330780 proximitor — they are not interchangeable.
- Signal: -2V to +18V over 250 mil (GFK-17744 §3)
- Proximitor: 330180-xx only
- Loop <= 30 m (GFK-18799 §7)
Is the armored variant (330104-01) electrically different from this standard probe?
No — armored and standard 330104 share identical 7.59 Ohm probe resistance, -50 to +175 C temperature range, and linear signal output; the only differences are cable construction (stainless steel braid on armored) and connector type (SMA on armored vs ClickLoc on standard). Never pay the armored premium for installations in steel conduit with no external cable forces.
- Resistance: 7.59 +/- 0.50 Ohm both (GFK-17744 §2)
- Temp: -50 to +175 C both (GFK-17744 §6)
- Min bend radius: armored 38mm / standard 25mm
Do I need to recalibrate when replacing my existing 330104 probe?
Same part number, identical loop length and proximitor configuration: verify the mid-range gap voltage (1.27mm / 0.050in) falls within +/-0.10 V of factory — no full recalibration needed. If you changed extension cables or probe position, run a full zero and span to avoid drift over temperature cycles.
- Mid-range target: ~9 V DC at 1.27mm
- Tolerance: +/-0.10 V at mid-range
- Recalib always after any loop length change
Frequently Asked Questions About the 330104-00-08-10-02-01
Can I use a 6m extension cable with this probe on a +150C bearing housing?
A standard 330130-060 cable has PPS-insulated inner conductor rated to the full 3300 XL range, so it works up to +175C — but the FEP jacket softens above +200C; route cable away from hot pipe runs and confirm actual jacket temperature. For sustained +250C use armored fluidloc 330130-060-11-05.
Is this probe factory calibrated or do I need to calibrate on arrival?
Every Bently 3300 XL probe ships with a factory calibration sheet showing zero and span at three gaps (0.020", 0.050", 0.080"). You do not calibrate the probe itself — confirm values match your loop and proximitor. If pairing with a different cable length than factory sheet, run one field calibration before service.