Bently Nevada 330104-01-08-50-01-CN Vibration Probe
Technical Specifications
Measuring Range: 0-2.5mm
Accuracy: ±0.02mm
Output Signal: -1V to -18V DC
Power Requirement: -17.5Vdc to -26Vdc
Resistance: 8.73 ± 0.50 Ω
Case Length: 80mm
Industrial Applications
Chemical plant mixer monitoring
Steel rolling mill vibration control
Water treatment pump diagnostics
Food processing conveyor systems
Automotive test rig measurements
Model Structure
330104-01-08-50-01-CN
• 01: 1mm unthreaded length
• 08: 80mm case length
• 50: 5.0m cable length
• 01: ClickLoc connector with protector
• CN: Country specific approval
Installation Guide
Set 1.27mm gap from target
Secure with M10x1 threaded mount
Verify Viton O-ring seal
Ground to equipment frame
Use connector protector
Keep cable away from heat
Compatible Systems
Bently Nevada 3300 XL monitors
3500 series protection systems
System 1 diagnostics platform
Most vibration analyzers
Shipping & Support
FedEx express delivery
UPS worldwide service
DHL air freight
12 month product warranty
24 hour technical support
Armored vs standard probe — which survives vibrating pipe environments?
Armored 330104-01 variants are mandatory when the probe cable is routed through vibrating pipe runs, near moving machinery, or in high-abrasion cable trays; the stainless steel braid provides approximately 200 kgf tensile protection while electrical parameters (7.59 Ohm, -50 to +175 C, linear signal) remain identical. The premium is wasted when cable is fully housed in steel conduit.
- Braid tensile: ~200 kgf
- Electrical identical to standard
- Armored min bend: 38mm / 1.5in
Drop-in replacement for old 3300 monitor?
Yes — armored and standard 330104 share the same -17.5 to -26 VDC power, -2 V to +18 V signal range, and PPS tip response; any 3300 XL or 3500 rack with matching 330180 proximitor accepts this probe; update gap calibration if the armored cable path length differs from old installation.
- Power: -17.5 to -26 VDC
- Signal: -2V to +18V
- No firmware change
Is the braid causing signal noise?
Armored braid actually suppresses EMI/RFI — the three real noise causes are: (1) braid ground loop (both ends grounded); ground only at proximitor chassis; (2) bent below 38mm min bend radius; (3) damaged SMA connector pins. Measure loop resistance first to rule out broken conductors.
- Min bend: 38mm / 1.5in
- Single-point grounding for shields
- Loop resistance ~7.59 Ohm total
Frequently Asked Questions About the 330104-01-08-10-01-cn
Can I use this CN-certified probe on a 3500 rack in North America?
Yes — CN (CCC) is a Chinese regional approval covering IEC 61010 safety; electrical and mechanical dimensions are identical to global 330104. Some North American facilities require UL/CSA marking for safety files, but technically the probe works anywhere.
What if I cut the armored probe internal cable?
The armored probe has 1m of internal cable — if cut, replace the full probe. Never splice broken PPS-insulated coaxial cable; the splice creates a capacitance discontinuity corrupting the signal. Order a new 330104-01-08-10-01-cn.
Explore the Bently Nevada 3300 Series