BMENOC0311 Schneider Electric Modicon M580 FactoryCast Ethernet Module
The Schneider Electric BMENOC0311 serves as an advanced networking coprocessor for the premium Modicon M580 ePAC platform. This intelligent Network module streamlines complex plant data routing by managing simultaneous Modbus TCP and EtherNet/IP I/O scanning services. Its high-performance FactoryCast Ethernet architecture delivers customizable, embedded web servers directly from the rack. This empowers control engineers with real-time graphical field diagnostics. It utilizes an integrated multiport switch with RSTP protection to secure high-availability ring topologies at the physical field device layer.
To safely unlock advanced web server customizations and port mirroring configurations, please refer to the engineering reference documentation.
Download Schneider BMENOC0311 Programming Manual and Datasheet Now
Oiltech Controls’s Insight
- The BMENOC0311 significantly unloads standard CPU processing strain by handling intensive communication traffic independently.
- It allows seamless multi-protocol integration across diverse field subnets without needing expensive protocol converters.
- The embedded switch supports port mirroring to give field technicians immediate deep packet sniffing capabilities.
- Its FactoryCast interface lets maintenance teams view live diagnostic screens via standard web browsers on any mobile device.
- For priority stock verification or wholesale pricing requests, email our sales support desk at info@oiltechcontrols.com.
Hardware System Compatibility
- Backplane Type Compatibility: Fits standard BMEXBP series Ethernet + X-Bus combined backplane racks perfectly.
- Media Architecture: Connects to double shielded twisted pair copper lines via three industrial RJ45 ports.
- Device Replacement: Supports automated Fast Device Replacement servers for seamless downstream hardware swap-outs.
Core Technical Specifications
- Brand and Model: Schneider Electric BMENOC0311
- Product Component Type: Communication module
- Network Port Configuration: 3 Ethernet RJ45 10/100 Mbit/s communication interfaces
- Backplane Medium: Direct high-speed Ethernet backplane data bus link
- Topology Protection: Embedded switch engine featuring active RSTP loop prevention
- Current Consumption V13+: Efficient 900 mA at 3.3 V DC for product versions 13 and above
- Current Consumption Legacy: 1800 mA at 3.3 V DC for product versions below 13
- Manufacturing Origin: France (FR)
- Physical Mass: Extremely lightweight modular build weighing only 0.4 lb (0.2 kg)
Local Diagnostic Indicators
- RUN LED: Solid green indicator verifies active communication processor execution.
- ERR LED: Solid red light warns of a module hardware or system configuration fault.
- ETH MS LED: Dual-color green/red indicator tracks localized Ethernet port configuration health.
- Eth NS LED: Dual-color green/red flag displays real-time external network connection status.
Global Shipping and Warranty Terms
- Fast Dispatch Protection: Orders receive precision industrial packing and secure warehouse dispatch within 24-28 hours.
- Premium Logistics Carriers: Shipped internationally via top-tier express air couriers including FedEx, UPS, and DHL.
- Package Contents: 1 x brand new Schneider Electric BMENOC0311 module enclosed in original protective factory packaging.
- Warranty Term: Fully secured by our trusted, comprehensive 12 months warranty safeguarding your system against hardware defects.
- Instant Technical Chat: Reach our responsive global distribution specialists via WhatsApp at +86 158 8020 0923.
Frequently Asked Questions (FAQ)
- Q: Why does the current consumption vary so greatly between the different versions of the BMENOC0311 module?
A: Schneider redesigned the internal power board for version 13 and higher, cutting energy draw from 1800 mA down to 900 mA. - Q: Can I insert the BMENOC0311 card into a legacy slot that only supports basic X-Bus communication?
A: No, this processing module must sit inside an Ethernet-enabled BMEXBP rack slot to establish backplane data connection. - Q: What are the main functional advantages of the FactoryCast configuration feature on this network card?
A: It allows you to build custom HTML web pages directly inside the module memory for low-cost asset tracking. - Q: How does the built-in FDR server function save time during unexpected field device breakdowns?
A: The FDR server automatically uploads configuration files and matching IP addresses to newly swapped field equipment instantly. - Q: How do I choose between the BMENOC0311 and a standard network module during system planning?
A: Choose the BMENOC0311 if your control loop needs simultaneous multi-protocol scanning, bandwidth management, or customizable browser diagnostics.
Related Long-Tail Keywords
- Schneider M580 FactoryCast communication module
- BMENOC0311 Modbus TCP I/O scanner config
- Modicon M580 Ethernet IP network switch
- BMEXBP rack compatible Ethernet module
- Schneider Electric FDR server network card
Copyright © 2026 Oiltech Controls Limited. https://www.oiltechcontrols.com/ All rights reserved.
All rights reserved.










Reviews
There are no reviews yet.