Product Overview
Model: IV-HG10 is a sensor amplifier main unit from the Keyence IV Series. It delivers high-speed inspection for automated lines. The unit supports 16 detection tools and 1 position adjustment tool. You can store up to 32 programs for flexible changeovers.
This amplifier pairs with IV-HG series cameras. It handles shape checks, color area, edge pixel, width, diameter, pitch, OCR, and more. Built-in EtherNet/IP, PROFINET, and FTP client protocols simplify plant integration. The NPN/PNP switchable output and 6 inputs / 8 outputs give direct control. Oiltech Controls supplies tested units with a 12-month warranty.
Technical Specifications
| Parameter | Value |
|---|---|
| Brand | Keyence |
| Model | IV-HG10 |
| Series | IV Series |
| Type | Sensor amplifier, main unit |
| Detection Tools | 16 tools (Shape, Color Area, Area, Edge Pixels, Width/Height, Diameter, Edge Presence, Pitch, Position Adjustment, High Speed Position Adjustment, OCR) |
| Position Adjustment | 1 tool |
| Programs | 32 |
| Supply Voltage | 24 VDC ±10% (ripple included) |
| Power Consumption | 0.8 A max (1.5 A max with IV-HG15 expansion, output load excluded) |
| Output Type | Open collector, NPN/PNP switchable, N.O./N.C. switchable, 26.4 V 50 mA max |
| Inputs | 6 (IN1 to IN6) |
| Outputs | 8 (OUT1 to OUT8) |
| Built-in Ports | RJ-45 8-pin (100BASE-TX/10BASE-T) |
| Protocols | FTP client, EtherNet/IP, PROFINET |
| Operating Temperature | 0 to +50°C (no freezing) |
| Relative Humidity | 35 to 85% RH (no condensation) |
| Protection Rating | Not available |
| Material | Main case: Polycarbonate |
| Weight | Approx. 150 g |
| Dimensions (H×W×D) | Not available |
| Lifecycle | Active; official Keyence production status confirmed (Last verified: 2026-09) |
Note: Measurement range, frequency response, sensitivity, linearity, resolution, and immunity data are not published for this amplifier. Use Keyence IV-HG series camera specs for those figures.
Installation Guide
- Mount the IV-HG10 on a DIN rail or flat panel. Keep 10 mm clearance for airflow.
- Connect 24 VDC power. Check polarity. Use a stable supply.
- Attach the IV-HG camera to the amplifier port. Tighten the connector.
- Wire inputs (IN1–IN6) and outputs (OUT1–OUT8). Use shielded cable for noise-heavy areas.
- Plug the RJ-45 cable for EtherNet/IP, PROFINET, or FTP.
- Set the NPN/PNP switch and N.O./N.C. switch before power-on.
- Do not block vents. Ambient must stay 0 to +50°C and 35 to 85% RH.
Debug and Maintenance Convenience
Use the 32 programs to store different inspection recipes. Switch between them via input or software. The 16 detection tools let you tune shape, color, edge, and OCR checks without extra hardware. The position adjustment tool corrects part misalignment. For maintenance, check the RJ-45 lock and terminal screws every 6 months. Clean the unit with a dry cloth. Do not use solvents. The polycarbonate case resists dust but not water. Keep it in a dry cabinet if the line is washed down.
Compatibility Notes
- Works with IV-HG series camera heads.
- Expansion unit IV-HG15 adds channels. Power draw rises to 1.5 A.
- Supports EtherNet/IP and PROFINET for PLC and robot links.
- FTP client sends images and results to a server.
- No communication expansion slot. Use built-in ports only.
- Open collector output works with 24 V PLC inputs (NPN or PNP).
Certification and Packaging
Certifications are not listed in the official spec for this model. Ask Oiltech Controls for current compliance documents. Package contents: 1x IV-HG10 amplifier, 1x quick guide. Camera and cables are sold separately. Warranty: 12 months from Oiltech Controls. Shipping: FedEx, UPS, DHL. Tracking provided.
Typical Applications and Diagnostics
- Assembly presence/absence checks on automotive lines.
- Color area sorting for packaging.
- Edge pixel and width measurement for connectors.
- OCR for date codes and lot numbers.
- Pitch inspection for gears and stamped parts.
Diagnostics: Use the 32 programs to compare good vs. bad runs. The unit reports tool pass/fail via outputs. Monitor FTP logs for image history. Check power draw if outputs misbehave. If the amplifier resets, verify 24 VDC ripple is within ±10%.
Why Buy From Oiltech Controls?
- 15+ years in industrial automation spare parts.
- Global shipment support to your site.
- Tested industrial surplus and refurbished options.
- 12-month warranty on every unit.
- Technical verification before shipment.
- Support for obsolete control systems.
Contact: info@oiltechcontrols.com or +86 158 8020 0923 (WhatsApp).
FAQ
Q: Does the IV-HG10 include a camera?
A: No. It is the amplifier main unit only.
Q: How many tools can run at once?
A: One detection tool per inspection, but you can chain up to 16 tools in a program.
Q: What is the output rating?
A: 26.4 V, 50 mA max, open collector.
Q: Can I use PROFINET and EtherNet/IP together?
A: No. Select one protocol at a time.
Q: Is the warranty valid for refurbished units?
A: Yes. Oiltech Controls gives 12 months on all tested stock.
Q: How fast is shipping?
A: FedEx, UPS, and DHL. Lead time depends on stock.
Copyright © 2026 Oiltech Controls Limited. All rights reserved.
Original Source: https://www.oiltechcontrols.com/










Reviews
There are no reviews yet.