Schneider Acti9 iC60N 4P C32 Miniature Circuit Breaker – 32A, C-Curve, 6kA
Model: iC60N 4P C32 | Brand: Schneider Electric | Series: Acti9 iC60
This 4-pole miniature circuit breaker protects industrial control panels and distribution boards. It combines thermal-magnetic trip with a C-curve for mixed loads. The iC60N 4P C32 delivers reliable 6 kA breaking capacity at 400V AC. It mounts on standard 35 mm DIN rail. Ideal for OEM machinery, building systems, and obsolete control cabinets.
Technical Specifications
| Parameter | Value |
|---|---|
| Brand | Schneider Electric |
| Model | iC60N 4P C32 |
| Series | Acti9 iC60 |
| Poles | 4P |
| Rated current | 32 A |
| Trip curve | C (8×In ±20%) |
| Breaking capacity | 6 kA @ 230/400V |
| Rated voltage | 400V AC |
| Frequency | 50/60 Hz |
| Operating temperature | -35 to 70 °C |
| Mounting | 35 mm DIN rail |
| Mechanical life | 20,000 cycles |
| Electrical life | 10,000 cycles |
| Dimensions (H×W×D) | 85 × 72 × 78.5 mm |
| Weight | 0.5 kg |
| Standard | EN/IEC 60898-1, EN/IEC 60947-2 |
| Lifecycle | Active (Last verified: 2026-09) |
Note: This device does not measure frequency response, sensitivity, or linearity. Those parameters apply to sensors, not circuit breakers.
Installation Guide
- Mount on 35 mm DIN rail. Use 4-pole spacing.
- Torque terminals to 2.5 N·m. Use copper conductors only.
- Verify 400V AC system voltage before wiring.
- Allow 50 mm clearance above and below for heat dissipation.
- Do not exceed 32 A continuous load per pole.
Commissioning and Maintenance
- Test trip manually with the Test button after installation.
- Check torque every 12 months. Retighten if loose.
- Replace after 10,000 electrical cycles or visible arc damage.
- Keep ambient temperature below 70 °C for full life.
Compatibility
This breaker fits all Acti9 iC60 accessories. It works with Schneider comb busbars, auxiliaries, and shunt trips. It replaces older iC60N 4P C32 units without rewiring. Compatible with 3-phase + neutral systems. Not compatible with DC-only circuits.
Certifications
EN/IEC 60898-1, EN/IEC 60947-2. CE marked. RoHS compliant. UL 1077 recognized (check local code).
Package List
- 1 × Schneider iC60N 4P C32 circuit breaker
- 1 × Installation instruction sheet
- 1 × Original packaging
Warranty and Shipping
12-month warranty covers defects in material and workmanship. Ships via FedEx, UPS, or DHL. Tracking number provided within 24 hours. Contact info@oiltechcontrols.com or +86 158 8020 0923 for urgent orders.
Typical Applications
- Industrial control panels and motor control centers
- Building distribution boards and sub-panels
- OEM machinery with 3-phase + neutral loads
- Replacement for obsolete Acti9 iC60 systems
- Data center power distribution (branch circuits)
Diagnostic Capabilities
The C-curve trips at 8×In ±20%. This handles inrush currents from motors and transformers. A Test button confirms mechanical operation. No electronic diagnostics. For fault tracing, use a clamp meter and insulation tester.
Why Buy From Oiltech Controls?
- 15+ years in industrial automation spare parts.
- Global shipment via FedEx, UPS, DHL.
- Tested industrial surplus and refurbished options.
- 12-month warranty on every breaker.
- Technical verification before shipment.
- Support for obsolete control systems.
FAQ
Q: Is this breaker new or refurbished?
A: We offer both. Contact us for current stock condition.
Q: Can I use it for 3-phase 400V?
A: Yes. It is rated 400V AC and 4P.
Q: What is the magnetic trip range?
A: 8×In ±20% for C-curve.
Q: Does it come with a warranty?
A: Yes, 12-month warranty.
Q: How fast is shipping?
A: FedEx, UPS, DHL. 2–5 business days typical.
Contact: info@oiltechcontrols.com | +86 158 8020 0923
Copyright © 2026 Oiltech Controls Limited. All rights reserved.
Original Source: https://www.oiltechcontrols.com/









Reviews
There are no reviews yet.