iC60N 2P C63 – Schneider Electric Acti9 Miniature Circuit Breaker
Schneider Electric iC60N 2P C63 is a 63A miniature circuit breaker from the Acti9 iC60 range. It uses a C-curve thermal-magnetic trip. This breaker protects against overload and short circuit. It fits 2-pole circuits up to 400V AC. The 6kA breaking capacity meets IEC 60898-1. It also complies with IEC 60947-2. The iC60N 2P C63 works in temperatures from -35°C to 70°C. It mounts on 35mm DIN rail. Mechanical life reaches 20,000 cycles. Electrical life reaches 10,000 cycles. This unit remains active in production as part of the Acti9 line.
Technical Specifications
| Brand | Schneider Electric |
| Model | iC60N 2P C63 |
| Series | Acti9 iC60 |
| Module Type | Miniature Circuit Breaker (MCB) |
| Poles | 2P |
| Rated Current | 63A |
| Trip Curve | C (magnetic trip 8×In ±20%) |
| Breaking Capacity | 6 kA @ 230/400V (IEC 60898-1) |
| Rated Voltage | 400V AC, 125V DC |
| Frequency Response | 50/60 Hz |
| Sensitivity | Thermal-magnetic (C curve) |
| Linearity | Stable trip threshold across rated current |
| Resolution | 1A step for current setting (fixed 63A) |
| Temperature Range | -35 to 70 °C |
| Environmental Resistance | Industrial indoor use, IEC 60947-2 |
| Anti-interference | Immune to common industrial noise |
| Mounting | 35 mm DIN rail |
| Mechanical Life | 20,000 cycles |
| Electrical Life | 10,000 cycles |
| Dimensions (H×W×D) | 85 × 36 × 78.5 mm |
| Weight | 0.25 kg |
| Standard | EN/IEC 60898-1, EN/IEC 60947-2 |
| Lifecycle | Active (Acti9 range, last verified 2026-09) |
Installation Guide
- Mount on 35 mm DIN rail.
- Use 2-pole wiring for 400V AC circuits.
- Tighten terminals to manufacturer torque.
- Keep -35 to 70 °C operating range.
- Do not exceed 6 kA short-circuit current.
Commissioning and Maintenance
- Test trip function with C-curve tester.
- Check mechanical operation every 20,000 cycles.
- Replace after 10,000 electrical cycles.
- Verify torque and connection tightness yearly.
Compatibility Notes
- Fits Acti9 iC60 distribution boards.
- Works with Schneider Electric busbars.
- Replaces standard 2P C63 MCBs.
- Compatible with 125V DC control circuits.
Certifications
- EN/IEC 60898-1
- EN/IEC 60947-2
Packing List
- 1 × Schneider Electric iC60N 2P C63 circuit breaker
- 1 × Product documentation
Warranty and Shipping
- 12-month warranty from Oiltech Controls.
- Shipping by FedEx, UPS, or DHL.
Typical Applications
- Industrial control panels
- Commercial distribution boards
- Machinery power circuits
- Obsolete system replacements
Diagnostic Capability
- Trip indicator shows C-curve activation.
- Visual check for overload or short circuit.
- Manual test button for function check.
Why Buy From Oiltech Controls?
- 15+ years in industrial automation spare parts.
- Global shipment support.
- Tested industrial surplus and refurbished options.
- 12-month warranty on every order.
- Technical verification before shipment.
- Support for obsolete control systems.
FAQ
Q: What is the trip curve of this breaker?
A: It uses a C-curve with magnetic trip at 8×In ±20%.
Q: Can this breaker work in DC circuits?
A: Yes, rated for 125V DC.
Q: What is the breaking capacity?
A: 6 kA at 230/400V per IEC 60898-1.
Q: How many poles does it have?
A: 2P (two poles).
Q: What is the warranty period?
A: 12 months from Oiltech Controls.
Q: Which couriers do you use?
A: FedEx, UPS, and DHL.
Q: Is this product still in production?
A: Yes, lifecycle is Active as of 2026-09.
Q: Can I get technical support for obsolete systems?
A: Yes, Oiltech Controls supports obsolete control systems.
Contact Information
Email: info@oiltechcontrols.com
Phone/WhatsApp: +86 158 8020 0923
Copyright © 2026 Oiltech Controls Limited. All rights reserved.
Original Source: https://www.oiltechcontrols.com/










Reviews
There are no reviews yet.