Keyence SJ-E156L Small Flow Bar Ionizer
The Keyence SJ-E156L is a small flow bar type static eliminator. It uses corona discharge with a shockless resistive coupling structure. The pulse AC method applies ±8000 V for strong ion output. The Hi-Power I.C.C. method holds ion balance at ±30 V. This model fits narrow spaces and long production lines. The 25 tungsten electrodes cover a wide area. The effective length reaches 1640 mm at 50 mm distance. Air pressure runs from 0.1 to 0.5 MPa. The recommended value is 0.2 MPa. Installation distance is 50 to 2000 mm. The total length is 1520 mm. Weight is only 1.70 kg.
Technical Specifications
| Brand | Keyence |
| Model | SJ-E156L |
| Series | SJ-E series |
| Product type | Bar-type static eliminator, small flow model |
| Ion generation | Corona discharge |
| Structure | Shockless resistive coupling |
| Voltage application | Pulse AC, ±8000 V |
| Ion balance control | Hi-Power I.C.C. |
| Ion balance | ±30 V at 300 mm or more, 0.2 MPa air pressure |
| Installation distance | 50 to 2000 mm |
| Number of electrodes | 25 |
| Effective length | 1640 mm at 50 mm static elimination range |
| Total length | 1520 mm |
| Supply voltage | 24 to 36 VDC ±10% |
| Current consumption | 700 mA at 24 V, 500 mA at 36 V |
| Output type | NPN open collector: ion level warning, condition warning, alarm output |
| Control input | Static elimination stop input, NPN open collector or contact point |
| Control output | NPN open collector, 100 mA max, 40 VDC or less |
| Air connection port | Rc 1/8 |
| Air supply pressure | 0.1 to 0.5 MPa, recommended 0.2 MPa |
| Overvoltage category | I |
| Pollution degree | 2 |
| Operating temperature | 0 to +40 °C |
| Relative humidity | 35 to 85 % RH, no condensation |
| Protection rating | Not available |
| Dimensions (H×W×D) | Not available, total length 1520 mm |
| Weight | 1.70 kg |
| Electrode probe material | Tungsten |
| Main body material | ABS, PBT, PP, LCP, PPS, SPS, SUS |
| Built-in ports | None |
| Protocols | Remote control communication |
| Communication expansion | None |
| Lifecycle | Active, official Keyence production status confirmed |
Installation Guide
- Place the bar 50 to 2000 mm from the target surface.
- Use the full 1640 mm effective length at 50 mm distance.
- Connect clean air to the Rc 1/8 port.
- Set pressure between 0.1 and 0.5 MPa. Target 0.2 MPa.
- Feed the unit with 24 to 36 VDC ±10%.
- Keep control output below 40 VDC and 100 mA.
- Operate between 0 and +40 °C.
- Keep humidity under 85 % RH. Avoid condensation.
Setup and Maintenance Convenience
The SJ-E156L uses NPN open collector signals for simple wiring. The static elimination stop input accepts NPN open collector or dry contact. Ion level warning, condition warning, and alarm output speed up fault finding. The Hi-Power I.C.C. control cuts manual tuning time. The shockless resistive coupling design protects operators. Maintenance focuses on keeping the 25 tungsten electrodes clean. No built-in port means the unit stays compact. Remote control communication handles external commands.
Compatibility Notes
- Matches common 24 VDC and 36 VDC industrial power rails.
- Remote control communication links to external control systems.
- No expansion port. Plan I/O at the system level.
- Use clean, dry air with a filter regulator.
- NPN output suits many PLC and motion controller inputs.
- Not rated for washdown or humidity above 85 % RH.
Certifications and Compliance
Overvoltage category I. Pollution degree 2. Keyence official production status is confirmed. Protection rating is not available. Check local electrical and safety rules before use. For certificates, email info@oiltechcontrols.com.
Packing List
- 1 × Keyence SJ-E156L bar-type static eliminator
- 1 × Quick start guide or official documentation copy as available
- Protective shipping packaging
- Accessories only as listed by the supplier
Warranty and Shipping
Every unit carries a 12-month warranty. We ship by FedEx, UPS, and DHL. Tracking goes out after dispatch. For urgent line down cases, message +86 158 8020 0923 on WhatsApp.
Typical Applications
- Film and sheet converting lines
- Packaging machinery with fast webs
- Printing and label equipment
- Plastic injection and blow molding areas
- Electronics assembly near sensitive parts
- Long lines needing a 1640 mm effective range
Diagnostic Capabilities
The unit reports ion level warning, condition warning, and alarm output. These NPN open collector signals help spot ion balance drift or maintenance needs. The Hi-Power I.C.C. method keeps ion balance stable. The ±30 V balance at 300 mm or more supports process reliability. Use the static elimination stop input to pause operation during service.
Why Buy From Oiltech Controls?
- 15+ years in industrial automation spare parts
- Global shipment support with FedEx, UPS, and DHL
- Tested industrial surplus and refurbished options
- 12-month warranty on eligible products
- Technical verification before shipment
- Support for obsolete control systems
Questions? Email info@oiltechcontrols.com or message +86 158 8020 0923 on WhatsApp.
FAQ
Q: What is the ion balance of the SJ-E156L?
A: It is ±30 V at 300 mm or more with 0.2 MPa air pressure.
Q: What voltage does it use?
A: It uses 24 to 36 VDC ±10%.
Q: How many electrodes does it have?
A: It has 25 electrodes.
Q: What is the effective length?
A: 1640 mm at 50 mm static elimination range.
Q: What air pressure is recommended?
A: 0.2 MPa is recommended. The range is 0.1 to 0.5 MPa.
Q: Does it have built-in communication ports?
A: No. It supports remote control communication only.
Q: What is the warranty?
A: 12 months.
Q: How fast is shipping?
A: We use FedEx, UPS, and DHL. Lead time depends on stock and destination.
Copyright © 2026 Oiltech Controls Limited. All rights reserved.
Original Source: https://www.oiltechcontrols.com/










Reviews
There are no reviews yet.