Product Description
Keyence IV-G500CA is a color sensor head for the IV-G10 amplifier. It belongs to the IV-G Series. This model is a standard field of view sensor head. It uses auto focus. It connects to the amplifier by a dedicated cable. No built-in port. No standalone protocol. All output and communication go through the amplifier.
The IV-G500CA suits inline inspection, color detection, and presence checking. It works at 20 to 500 mm install distance. The view size changes with distance. At 20 mm, the view is 10 x 7.5 mm. At 500 mm, the view is 200 x 150 mm. The 1/3 inch color CMOS gives 752 x 480 pixels. White LED lighting supports pulse and DC modes.
Note: Keyence marks this model as discontinued. A recommended replacement is listed on the official product page. Last verified: 2026-09. Oiltech Controls supplies tested surplus and refurbished options for obsolete systems.
Technical Specifications
| Brand | Keyence |
| Model | IV-G500CA |
| Series | IV-G Series |
| Module Type | Color sensor head, standard field of view |
| Compatible Amplifier | IV-G10 |
| Install Distance | 20 to 500 mm |
| Field of View | 20 mm: 10 (H) x 7.5 (V) mm; 500 mm: 200 (H) x 150 (V) mm |
| Image Sensor | 1/3 inch color CMOS, 752 (H) x 480 (V) pixels |
| Focus Adjustment | Auto |
| Illumination | White LED |
| Lighting Method | Pulse lighting / DC lighting, switchable |
| Resolution | 752 x 480 pixels |
| Response / Frequency | Via IV-G10 amplifier |
| Sensitivity / Linearity | Via IV-G10 amplifier setup |
| Temperature Range | 0 to +50°C, no freezing |
| Humidity | 35 to 85% RH, no condensation |
| Protection Rating | IP67 |
| Noise Immunity | Depends on amplifier and cable routing |
| Supply Voltage | Supplied by connected amplifier |
| Power Consumption | Not available |
| Output Type | Via amplifier |
| Built-in Ports | None |
| Protocols | None |
| Communication Expansion | Via amplifier |
| Dimensions (H x W x D) | Not available |
| Weight | Approx. 75 g |
| Lifecycle | Discontinued; replacement recommended by Keyence |
Installation Guide
- Mount the IV-G500CA at 20 to 500 mm from the target.
- Keep the head square to the target surface.
- Use the dedicated cable to connect to the IV-G10 amplifier.
- Set the install distance before auto focus runs.
- Check the view size at your chosen distance.
- Avoid strong direct light and reflective background.
- Keep cable routes away from high-power lines.
- Confirm IP67 sealing after mounting.
Setup and Maintenance
Setup is simple. Connect the head to the IV-G10. Power the amplifier. Let auto focus lock. Then set color thresholds in the amplifier menu. Use pulse lighting for moving targets. Use DC lighting for static targets.
Maintenance is low. Clean the lens with a soft cloth. Check the cable for cuts. Check the connector for water ingress. Keep the ambient temperature within 0 to +50°C. Keep humidity within 35 to 85% RH. Do not use in condensing conditions.
Compatibility
- Works only with the IV-G10 amplifier.
- Uses a dedicated cable, not a standard port.
- Output and communication depend on the amplifier.
- Not a standalone sensor. No direct PLC link.
- Check amplifier firmware and cable part number before order.
Certifications and Compliance
Certification details are not listed in the source data. Please confirm with Keyence or ask our team. We can check labels and test reports before shipment. Protection rating: IP67. Operating temperature: 0 to +50°C. Humidity: 35 to 85% RH.
Packing List
- 1 x Keyence IV-G500CA sensor head
- Protective packing
- Test record from Oiltech Controls
- Dedicated cable not included unless stated
- Amplifier IV-G10 not included
Warranty and Shipping
All units come with a 12-month warranty. We test before shipment. We support obsolete control systems. Shipping by FedEx, UPS, and DHL. Tracking is provided. Contact us for lead time and stock status.
Typical Applications
- Color mark detection on packaging lines
- Presence and position checks on small parts
- Inline inspection in tight spaces
- Obsolete IV-G Series replacement
- Automated assembly cells
- Label and print verification
Diagnostic Capability
The IV-G500CA has no self-diagnostic output of its own. All diagnostics run through the IV-G10 amplifier. The amplifier shows focus status, light level, and detection result. It can flag unstable readings. It can also help with threshold tuning. For best results, keep the lens clean and the target stable.
Why Buy From Oiltech Controls?
- 15+ years in industrial automation spare parts
- Global shipment support
- Tested industrial surplus and refurbished options
- 12-month warranty
- Technical verification before shipment
- Support for obsolete control systems
FAQ
Q: Does the IV-G500CA work alone?
A: No. It needs the IV-G10 amplifier.
Q: What is the install distance?
A: 20 to 500 mm.
Q: Is auto focus included?
A: Yes. Focus adjustment is auto.
Q: What is the protection rating?
A: IP67.
Q: What is the warranty?
A: 12 months.
Q: How do you ship?
A: FedEx, UPS, and DHL.
Q: Is this model discontinued?
A: Yes. Keyence lists it as discontinued. We supply tested options for legacy systems.
Contact Us
Email: info@oiltechcontrols.com
WhatsApp: +86 158 8020 0923
Copyright © 2026 Oiltech Controls Limited. All rights reserved.
Original Source: https://www.oiltechcontrols.com/










Reviews
There are no reviews yet.