iC60N 3P C32 Acti9 Miniature Circuit Breaker by Schneider Electric
Schneider Electric iC60N 3P C32 is a 3-pole miniature circuit breaker from the Acti9 iC60 series. It protects industrial circuits against overload and short circuit. The C-curve trips at 8×In ±20%. Breaking capacity reaches 6 kA at 230/400V. This model suits 400V AC distribution, control panels, and OEM machines. The Acti9 range remains active in production. Last verified: 2026-09.
Technical Specifications
| Brand | Schneider Electric |
| Model | iC60N 3P C32 |
| Series | Acti9 iC60 |
| Module Type | Miniature Circuit Breaker (MCB) |
| Poles | 3P |
| Rated Current | 32 A |
| Trip Curve | C curve, thermal-magnetic |
| Magnetic Trip | 8×In ±20% |
| Breaking Capacity | 6 kA at 230/400V (IEC 60898-1) |
| Rated Voltage | 400V AC |
| Frequency | 50/60 Hz (standard AC network) |
| Measuring Range | Up to 32 A rated current |
| Sensitivity | Thermal and magnetic trip response |
| Linearity | Stable thermal-magnetic characteristics |
| Resolution | Circuit-level protection, not metering |
| Temperature Range | -35 to 70 °C |
| Environmental Resistance | Industrial panel environment |
| Interference Immunity | Meets IEC 60898-1 and IEC 60947-2 |
Installation Guide
- Mount on a 35 mm DIN rail.
- Use 3-pole wiring for 400V AC circuits.
- Torque terminals to Schneider specifications.
- Verify 32 A load before energizing.
- Keep panel temperature within -35 to 70 °C.
- Allow space for 85 × 54 × 78.5 mm body.
Commissioning and Maintenance Convenience
The iC60N 3P C32 supports fast commissioning. The DIN rail clip speeds up panel assembly. Clear ON/OFF status helps visual checks. Mechanical life reaches 20,000 cycles. Electrical life reaches 10,000 cycles. Routine maintenance needs no special tools. Replace units only after trip testing or damage. Weight is 0.375 kg for easy handling.
Compatibility Notes
This MCB fits Acti9 iC60 accessories and standard 35 mm DIN rail systems. It works with 400V AC distribution boards. It replaces many 3P C32 MCBs in industrial panels. Check busbar pitch and terminal space before fitting. The 6 kA rating suits common commercial and industrial feeders. Confirm coordination with upstream and downstream devices.
Certifications and Standards
- EN/IEC 60898-1
- EN/IEC 60947-2
- CE marking per Schneider Electric
- RoHS and REACH compliance per brand
- Acti9 range lifecycle: Active
Packing List and Warranty
- 1 × Schneider Electric iC60N 3P C32 MCB
- 1 × Product label and packaging
- 12-month warranty from Oiltech Controls
- Technical verification before shipment
- Shipping by FedEx, UPS, or DHL
Typical Applications
- Industrial control panels
- OEM machinery feeders
- Building distribution boards
- Motor and lighting circuits
- Obsolete control system replacement
- 3-phase 400V AC branch protection
Diagnostic Capability
The C-curve responds to overload and short circuit. Thermal trip handles gradual overload. Magnetic trip handles high fault current. The 8×In ±20% magnetic threshold supports motor and transformer loads. A trip indicates fault or overload. Reset after clearing the fault. If trips repeat, check load, wiring, and downstream devices.
Why Buy From Oiltech Controls?
- 15+ years in industrial automation spare parts
- Global shipment support through FedEx, UPS, and DHL
- Tested industrial surplus and refurbished options
- 12-month warranty on eligible products
- Technical verification before shipment
- Support for obsolete control systems
Inquiries: info@oiltechcontrols.com or +86 158 8020 0923.
FAQ
Q: What is the model?
A: iC60N 3P C32 from Schneider Electric.
Q: What curve does it use?
A: C curve with magnetic trip at 8×In ±20%.
Q: What is the breaking capacity?
A: 6 kA at 230/400V per IEC 60898-1.
Q: How many poles?
A: 3P for three-phase circuits.
Q: What is the rated current?
A: 32 A.
Q: What voltage?
A: 400V AC.
Q: What is the temperature range?
A: -35 to 70 °C.
Q: How does it mount?
A: On a 35 mm DIN rail.
Q: What is the mechanical life?
A: 20,000 cycles.
Q: What is the electrical life?
A: 10,000 cycles.
Q: What are the dimensions?
A: 85 × 54 × 78.5 mm.
Q: What is the weight?
A: 0.375 kg.
Q: Which standards apply?
A: EN/IEC 60898-1 and EN/IEC 60947-2.
Q: Is the lifecycle active?
A: Yes, Active in the Acti9 range.
Q: What warranty applies?
A: 12-month warranty from Oiltech Controls.
Q: How does it ship?
A: By FedEx, UPS, or DHL.
Q: Can it replace obsolete breakers?
A: Yes, with technical verification before shipment.
Q: How do I contact sales?
A: Email info@oiltechcontrols.com or WhatsApp +86 158 8020 0923.
Copyright © 2026 Oiltech Controls Limited. All rights reserved.