GL-VM30LN Keyence Safety Light Curtain: 1200 mm Body Guarding for Long Openings
The GL-VM30LN extends the Keyence GL-V series to tall body-access zones. It runs 30 beam axes across a 1160 mm detection height. The 40 mm beam spacing targets torso and limb entry, not finger contact. NPN output suits PLC inputs common in Asian and European panels. A 1200 mm total length covers full operator walk-in areas on presses, wrappers, and robot cells.
Core Specifications
- Model: GL-VM30LN
- Brand: Keyence
- Series: GL-V series
- Type: Type 4 ESPE / AOPD, body protection
- Beam axes: 30 axes, 40 mm spacing
- Detection height: 1160 mm
- Total length: 1200 mm
- Detectable object: ø45 mm
- Range: 0.3 to 15 m
- Response time: max. 5.1 ms (OSSD, channel 0, ON→OFF)
- Output: NPN transistor x2 (OSSD)
- Weight: 780 g transmitter, 790 g receiver
Electrical Profile
- 24 VDC supply with -20/+25% tolerance and 10% ripple.
- Transmitter draws 128 mA; receiver draws 142 mA with indicator ON.
- Maximum load current sits at 150 mA or less.
- ON residual voltage reaches 2.5 V; OFF voltage stays below 2.0 V.
- Leakage current maxes at 0.8 mA with 0.8 µF load capacity.
- Load wiring resistance should not exceed 2.5 Ω.
- Short-circuit input current sits near 3 mA.
Mechanical and Environmental Ratings
- Main body uses aluminum alloy for rigidity.
- Upper and lower case use PPS with 40% glass fiber.
- Front cover combines polycarbonate and SUS304.
- Operating temperature spans -30 to +55 °C without freezing.
- Storage temperature spans -30 to +70 °C.
- Humidity tolerance reaches 95% RH without condensation.
- Ambient light immunity handles 3,000 lux incandescent and 20,000 lux sunlight.
- IP65/IP67 rating supports washdown and dust-heavy floors.
- Vibration resistance covers 5 to 150 Hz at 1G in X, Y, Z.
- Shock resistance handles 15 G pulses for 6 ms, 100 times per axis.
Optical and Safety Logic
- Infrared LED at 850 nm falls under Exempt Group IEC62471.
- Effective angular aperture reaches ±2.5° at 3 m or more.
- Detection turns ON only when all 30 beam axes are received.
- Optical synchronization removes the sync cable between units.
- Interference prevention supports 2 units via series connection.
- Protection circuits cover reverse connection, short circuit, and surge.
Compliance and Certifications
- IEC61496-1/-2 Type 4 ESPE / AOPD
- EN ISO13849-1 Category 4, PL e
- IEC61508 SIL3
- UL60947-1 and CSA C22.2 No.60947-1
- UL1998
- EMC: EN55011 Class A, FCC Part15B Class A, ICES-003 Class A
NPN vs PNP: Which GL-V Model Fits Your Panel?
- GL-VM30LN uses NPN output for sinking PLC inputs.
- GL-VM40HP and GL-VM04LP use PNP for sourcing inputs.
- Pick NPN when your safety relay or PLC input pulls to 0 V.
- Pick PNP when your input expects a positive voltage signal.
- Mixing output types on one machine adds wiring complexity.
- Match the output to your existing panel standard first.
Recommended Equipment Pairings
- Hydraulic and mechanical press bodies
- Robot cell entry doors and gates
- Palletizing and depalletizing stations
- Large packaging and wrapping machines
- Vertical storage lift openings
- Legacy GL-V replacements where 1200 mm length is fixed
Why Buy From Oiltech Controls?
- We draw on more than 15 years of industrial automation spare parts work.
- We ship worldwide through FedEx, UPS, and DHL.
- We stock tested surplus and professionally refurbished units.
- Every order carries a 12-month warranty.
- We test and verify each unit before it leaves our floor.
- We keep obsolete and discontinued control systems alive.
- Most orders dispatch within 24 to 28 hours.
FAQ: GL-VM30LN Selection and Experience
Q: Can this model detect a hand instead of a body?
A: No. The ø45 mm resolution suits body protection. Use a 20 mm or 25 mm pitch model for hand or finger detection.
Q: My PLC input is sourcing. Will NPN work?
A: No. NPN sinks current to 0 V. Choose the PNP version of the GL-V series for sourcing inputs.
Q: How do I calculate the safety distance?
A: Use ISO 13855 with the 5.1 ms response time plus your machine stop time and approach speed.
Q: Can I run two GL-VM30LN sets side by side?
A: Yes. Series connection and switch setting prevent interference for up to 2 units.
Q: Should I buy surplus or refurbished for a legacy line?
A: Buy tested surplus when the fixture is fixed and budget is tight. Buy refurbished when the model is discontinued but the mounting stays.
Oiltech Controls Review: Field Notes on the GL-VM30LN
- The 1200 mm length rarely needs cutting or adapters on standard press guards.
- NPN output simplifies retrofits on older Japanese and Asian control panels.
- Low current draw avoids overloading small 24 VDC supplies.
- Optical sync cuts installation time on long runs.
- Always confirm the 1160 mm detection height against your actual opening.
Contact Oiltech Controls
Email: info@oiltechcontrols.com
WhatsApp: +86 158 8020 0923
Copyright © 2026 Oiltech Controls Limited. https://www.oiltechcontrols.com/ All rights reserved.










Reviews