330701-00-20-10-11-00 vs 330701-00-30-10-02-00 — Bently Nevada 3300 XL 1/2-20 UNF Proximity Probe Cable Length and Connector Comparison

330701-00-20-10-11-00 vs 330701-00-30-10-02-00 — Bently Nevada 3300 XL 1/2-20 UNF Proximity Probe Cable Length and Connector Comparison

Which Bently Nevada 330701 part number should I buy — 00-20 or 00-30?

The short answer: choose -00-20-* for most 3500 rack installations where cable distance is under 20 m from probe to proximitor, and -00-30-* for distributed I/O, long raceways or when you need the extra meter margin. The other four blocks (thread, armor, connector, approval) are identical across all 330701 family members — only the BBB cable-length block changes.

Side-by-side comparison

Feature 330701-00-20-10-11-00 330701-00-30-10-02-00
Thread family 1/2-20 UNF 1/2-20 UNF
Cable length 20 m 30 m
Armor No (CC=10) No (CC=10)
Connector ClickLoc + FluidLoc ClickLoc + protector only
Approval ATEX Zone 0 Ex ia IIC T5 ATEX Zone 2 Ex nA
Temperature -52°C → +177°C -52°C → +177°C
Frequency 0–8 kHz 0–8 kHz
Linear range 4.0 mm (160 mil) 4.0 mm (160 mil)

When to pick 330701-00-20-10-11-00

The -11 block means FluidLoc. FluidLoc is a mechanical seal inside the ClickLoc coupling that prevents lube oil, condensate or wet steam from wicking past the threads and fouling the center conductor. If your probe touches wet steam, water-injection or heavily contaminated lube oil, FluidLoc is mandatory — the standard ClickLoc leaks under pressure and your zero will drift within 30 days.

20 m cable is the standard for most turbines where the proximitor sits 12–18 m from the probe tip. You have 2 m of slack for pulling through raceways and dressing.

When to pick 330701-00-30-10-02-00

30 m cable gives you 10 m of extra reach. Buy this when:
– Your 3500 rack is in a remote control room and the field wiring is 22–28 m
– You have to pull the cable through multiple junction boxes
– You are retrofitting an old 3500 rack from 7200 probes and your existing raceway was run for longer distances

The -02 connector block means standard ClickLoc with tip protector only (no FluidLoc). Fine for dry industrial gas turbines and compressors.

All 330701-00-30 variants you can stock

Part number Connector Approval
330701-00-30-10-02-00 ClickLoc + protector Zone 2
330701-00-30-10-02-01 ClickLoc + protector Zone 0 not required
330701-00-30-10-02-02 ClickLoc + protector Zone 0 Ex ia

Block EE-01 removes the Zone 0 approval documentation so lead time drops by 4–6 weeks if your site only needs Zone 2 Ex nA.

Cable length matters more than people think

The 3300 XL system uses 75 Ω triaxial field wiring with a white inner coaxial. Attenuation is 0.7 dB/100 m at 8 kHz. At 30 m that is 0.21 dB, well within the 3 dB budget. If you need longer, run a 3300 XL extension cable (same 75 Ω triaxial) — the system supports up to 305 m total (probe → proximitor → monitor).

Never mix 330701 with 330707 or 330703 probes

They are all 11 mm diameter, but the thread forms are not interchangeable. A 1/2-20 UNF probe threaded into a 5/8-18 UNF or M14 housing bores the wrong pitch and will not seat on the calibration datum plane. The proximitor sees a 0.3 mm offset and every axial reading is wrong from day one.

Related guides

1. What is the maximum cable length for 330701 series probes?

Baker Hughes specifies 305 m (1,000 ft) total field wiring including the extension cable from probe to proximitor to monitor. Individual probe cables ship up to 50 m (BBB=050). For longer distances you splice with 75 Ω triaxial extension cable — do not use generic RG-58.

2. Can I add FluidLoc to an existing 330701-00-30-10-02-00 probe?

No. FluidLoc is machined into the probe connector during manufacture. The -02 ClickLoc body cannot be retrofitted with FluidLoc. If you need FluidLoc, order the part number with DD=11. Baker Hughes does not sell upgrade kits.